Mounting details for SR axis flag and sensor
Auteur Gareth Green | Dernière modification 4/12/2023 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Mounting details for SR axis flag and sensor
R0015085_Mount_SR_Datum_Sensor_and_Flag_Screenshot_2023-10-20_075214.png
Tools Required
Standard Hex key set
Standard spanner set
Parts required
D0015489 Saw Turntable Sensor Bar x 1
E0000336 Sensor: M8; 2mm, PNP N/O, M8 conn x 1
M0001165 U bolt 3nb M12 BZP x 1
All bolts to have Loctite 243 adhesive applied unless otherwise stated
All Threaded Pneumatic connections to have Loctite 570 applied
All bolts to be pen marked once adhesive applied and correct tension added
Attach u bolt and sensor bracket on infeed mounting pillar
Fix with M12 nuts and M12 A form washers
Set sensor height to minimal clearance (-1mm )
Check gap is consistent on full travel over sensor flag when head is rotated
Finalise M12 nuts and ensure U bolt assembly is mounted true as to not impact on side sheet guarding panel when fitted later