Blower
With the Autoflow SR Axis bearing system change to a hepco rail system, issues have occurred due to swarf blockage.
A system has been designed to combat the issue in 2 ways; Blowers to pevent swarf build up and scrapers to keep the journals clear of swarf
Blowers
The blowers will run from a new valve to be installed on the saw turret
Scrapers