Setting Delrin Transfer Table Wheel Tension : Différence entre versions

[version en cours de rédaction][version approuvée]
(Page créée avec « {{Tuto Details |Description=<translate>How to set the tension on the Delrin / Oozenest jounal to prevent premature failure</translate> |Categories=Maintenance |Difficulty=... »)
 
 
Ligne 1 : Ligne 1 :
 
{{Tuto Details
 
{{Tuto Details
 +
|Main_Picture=Setting_Delrin_Transfer_Table_Wheel_Tension_Screenshot_2022-04-06_083722.jpg
 +
|Main_Picture_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":0,"top":0,"width":1242,"height":1035,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":0.49,"scaleY":0.49,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/e/e3/Setting_Delrin_Transfer_Table_Wheel_Tension_Screenshot_2022-04-06_083722.jpg","filters":[]}],"height":450,"width":600}
 
|Description=<translate>How to set the tension on the Delrin / Oozenest jounal to prevent premature failure</translate>
 
|Description=<translate>How to set the tension on the Delrin / Oozenest jounal to prevent premature failure</translate>
 
|Categories=Maintenance
 
|Categories=Maintenance
Ligne 20 : Ligne 22 :
 
Adjustment is via an 8mm spanner on the bearing stem
 
Adjustment is via an 8mm spanner on the bearing stem
  
The tension onto the rail should be adjusted so that the rotation of the journal is still able to be stopped between the thumb and forefinger.
+
The tension onto the rail should be adjusted so that:
 +
 
 +
* the Journals are touching top and bottom
 +
* Rotation of the journal is still just possible (but tight) between the thumb and forefinger
  
 
<br />{{Warning|...It is very easy to overtighten this journal and it will still appear to work}}<br /></translate>
 
<br />{{Warning|...It is very easy to overtighten this journal and it will still appear to work}}<br /></translate>
 
|Step_Picture_00=Setting_Delrin_Transfer_Table_Wheel_Tension_Screenshot_2022-04-06_083722.jpg
 
|Step_Picture_00=Setting_Delrin_Transfer_Table_Wheel_Tension_Screenshot_2022-04-06_083722.jpg
 
|Step_Picture_01=Setting_Delrin_Transfer_Table_Wheel_Tension_Screenshot_2022-04-06_083752.jpg
 
|Step_Picture_01=Setting_Delrin_Transfer_Table_Wheel_Tension_Screenshot_2022-04-06_083752.jpg
 +
|Step_Picture_01_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":0,"top":0,"width":547,"height":315,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1.1,"scaleY":1.1,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/b/b4/Setting_Delrin_Transfer_Table_Wheel_Tension_Screenshot_2022-04-06_083752.jpg","filters":[]},{"type":"textbox","version":"2.4.6","originX":"center","originY":"center","left":147.18,"top":166,"width":191.97,"height":101.25,"fill":"#0054FF","stroke":"#0054FF","strokeWidth":1,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1,"scaleY":1,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"text":"Wheel should still just be able to rotate between finger and thumb","fontSize":20,"fontWeight":"normal","fontFamily":"sans-serif","fontStyle":"normal","lineHeight":1.16,"underline":false,"overline":false,"linethrough":false,"textAlign":"left","textBackgroundColor":"","charSpacing":0,"minWidth":20,"styles":{} }],"height":346,"width":600}
 
}}
 
}}
 
{{Tuto Step
 
{{Tuto Step
Ligne 34 : Ligne 40 :
 
{{Notes}}
 
{{Notes}}
 
{{PageLang
 
{{PageLang
 +
|Language=en
 
|SourceLanguage=none
 
|SourceLanguage=none
 
|IsTranslation=0
 
|IsTranslation=0
|Language=en
 
 
}}
 
}}
 
{{Tuto Status
 
{{Tuto Status
 
|Complete=Draft
 
|Complete=Draft
 
}}
 
}}

Version actuelle datée du 6 avril 2022 à 11:26

Auteur avatarGareth Green | Dernière modification 6/04/2022 par Gareth Green Validée

How to set the tension on the Delrin / Oozenest jounal to prevent premature failure

Introduction

The "Delrin" or "Oozenest" system used on the transfer table rails is a simple, compact and low friction solution for linear transport.

However, it can be susceptible to premature failure if the journals are under too much tension. This tension forces the V shaped journals apart. If unchecked, and the journal fails, the aluminium rail will then be worn away.

Étape 1 - Adjust top loading

The top journals are eccentric.

Adjustment is via an 8mm spanner on the bearing stem

The tension onto the rail should be adjusted so that:

  • the Journals are touching top and bottom
  • Rotation of the journal is still just possible (but tight) between the thumb and forefinger

...It is very easy to overtighten this journal and it will still appear to work


Étape 2 - Ensure the rack is not "overmeshed"

...If the rack is adjusted to "heavily" it will push too hard upwards on the bottom roller