Setting Ultrasonic Sensor - Horizontal : Différence entre versions

[version en cours de rédaction][version en cours de rédaction]
Ligne 1 : Ligne 1 :
 
{{Tuto Details
 
{{Tuto Details
 
|Main_Picture=Setting_Ultrasonic_Sensor_-_Horizontal_IMG_1313.jpg
 
|Main_Picture=Setting_Ultrasonic_Sensor_-_Horizontal_IMG_1313.jpg
|Description=<translate>Setting an ultrasonic sensor mounted vertically</translate>
+
|Description=<translate>Setting an ultrasonic sensor mounted horizontally</translate>
 
|Difficulty=Easy
 
|Difficulty=Easy
 
|Duration=5
 
|Duration=5

Version du 10 septembre 2019 à 17:54

Auteur avatarGareth Green | Dernière modification 18/04/2024 par Gareth Green en cours de rédaction

Introduction

This involves setting a "window" for a minimum and maximum range when mounted horizontally

Video d'introduction

Étape 1 - Ensure there is 30mm clearance from sensor to profile

The sensor will not work unless there is 30mm clearance to minimum position



Étape 2 - Place Profile at minimum position

Usually with profile against backfence



Étape 3 - Press and hold button until lights flash

Around 3 seconds



Étape 4 - Place profile at maximum position

On an Ecoline, around 60mm



Étape 5 - Press and hold until lights stop flashing



Étape 6 - Test with profile

Ensure it turns off and on in the set window



Commentaires

Draft