|Introduction=<translate>With the development of full colour ranges for profiles, the older flowline opto sensors often have trouble "seeing" the darker profiles. An upgrade kit is available (R0019014) to replace the optical sensors with an ultrasonic version</translate> | |Introduction=<translate>With the development of full colour ranges for profiles, the older flowline opto sensors often have trouble "seeing" the darker profiles. An upgrade kit is available (R0019014) to replace the optical sensors with an ultrasonic version</translate> | ||
}} | }} | ||
− | {{Materials}} | + | {{Materials |
+ | |ItemList={{ItemList | ||
+ | |Item=R0019014 | ||
+ | }} | ||
+ | }} | ||
{{Tuto Step | {{Tuto Step | ||
|Step_Title=<translate>Kit of Parts</translate> | |Step_Title=<translate>Kit of Parts</translate> |
Upgrading the 3 off opto sensors on a flowline Mk3 infeed table to ultrasonic version
Auteur Gareth Green | Dernière modification 31/03/2020 par Stuga Engineer en cours de rédaction ⧼frevu-button-review-label⧽
Upgrading the 3 off opto sensors on a flowline Mk3 infeed table to ultrasonic version
flowline, ultrasonic, infeed, sensor, upgrade Upgrade_Flowline_Opto_Sensors_to_Ultrasonic_IMG_0130_-_Copy.jpg
The blower should Tee in to the blower already there for the other offcut measurement sensors