[version en cours de rédaction] | [version en cours de rédaction] |
Ligne 102 : | Ligne 102 : | ||
X294 | X294 | ||
+ | |||
+ | |||
+ | The ends of the E0000439 cables that have plugs on need to be tie wrapped 360mm from the teeth of the energy chain 'comb' to the plug ends. | ||
Assembly details for X axis energy chain
Auteur Gareth Green | Dernière modification 16/11/2023 par Stuga Engineer en cours de rédaction ⧼frevu-button-review-label⧽
Assembly details for X axis energy chain
R0015286B_Bench_Assemble_X_axis_Energy_Chain_Screenshot_2023-08-18_092205.png
Tools Required
Small flat screwdriver
Identification markers
Parts Required
A0001112 Energy Chain Separator: 2500 Chain x 20
A0001113 Energy Chain: Series 2500.03 55mm Bend Radius x 4.2 meter
A0001114 Energy Chain Bracket Set: 24/2500 Plastic, Pivoting x 1
E0000439 Connector Brad Harrison M8 3 pole 10 m lead pvc x 2
E0001237 Pre Made Cable :Beckoff Extension AM8032 9.0m x 11 Assemble 93 links together , ensure all links are orientated the same way .
2 Identify the female end of the assembled links
3 Fit 2 more links of A0001113, but fit in a reversed orientation
Attach mounting brackets A0001114
1 Attach male bracket to reversed links and orientated as shown, This end will be identified as A
2 Attach female bracket to opposite end orientated as shown. This end will be identified as B
1 Open all links of trunking using a small flat screwdriver to release
2 Fit A0001112 Energy Chain Separator to the following positions
Start from end A , fit 2 separators to first reversed link.
3 Counting from the first separators fitted, fit additional separators to every tenth link
4 This is correct. There will be 4 links with no separator between last fitted separators and mounting bracket
Add identification markers to 2 off E0000439 cables
X291
X294
The ends of the E0000439 cables that have plugs on need to be tie wrapped 360mm from the teeth of the energy chain 'comb' to the plug ends.
Fit cables to energy chain in section 1 as shown. Female Plugs should exit energy chain at End A . Leave 1 meter of cable to exit from plug end
Use Cable E0001237 Pre Made Cable :Beckoff Extension AM8032 9.0m x 1 and identify as 'SXA'
Fit to section 2 and leave Female plug and 0.5meter of cable to exit energy chain at the male bracket / reversed link end
Cut 3 0ff lengths of 6mm x 4mm black air pipe at 9 meters
Add identification as follows
2419
1311
1319
Fit to section 3 and leave 1 meter of pipe exiting the energy chain at the male bracket / reversed link end