R0015027 Install Pneumatic Connection rail and Air Feeds : Différence entre versions

[version en cours de rédaction][version en cours de rédaction]
(Page créée avec « {{Tuto Details |Main_Picture=R0015027_Install_Pneumatic_Connection_rail_and_Air_Feeds_Screenshot_2023-10-30_103843.png |Main_Picture_annotation={"version":"2.4.6","objects... »)
 
Ligne 48 : Ligne 48 :
 
}}
 
}}
 
{{Tuto Step
 
{{Tuto Step
|Step_Title=<translate></translate>
+
|Step_Title=<translate>Fit connection rail</translate>
|Step_Content=<translate></translate>
+
|Step_Content=<translate>Fit pre assembled connection rail</translate>
 +
|Step_Picture_00=R0015027_Install_Pneumatic_Connection_rail_and_Air_Feeds_Screenshot_2023-10-30_103843.png
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Add energy chain mounting brackets</translate>
 +
|Step_Content=<translate>Fit energy chain mounting brackets to cylinder rails</translate>
 +
|Step_Picture_00=R0015027_Install_Pneumatic_Connection_rail_and_Air_Feeds_Screenshot_2023-10-30_110219.png
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Connect energy chains from modules</translate>
 +
|Step_Content=<translate>Connect fitted energy chains from modules C and E to brackets</translate>
 +
|Step_Picture_00=R0015027_Install_Pneumatic_Connection_rail_and_Air_Feeds_Screenshot_2023-10-30_110219.png
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Add Y connections</translate>
 +
|Step_Content=<translate>Break into feed lines on cylinder rails with 6mm y fittings</translate>
 +
|Step_Picture_00=R0015027_Install_Pneumatic_Connection_rail_and_Air_Feeds_Screenshot_2023-10-30_110404.png
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Connect Feed pipes</translate>
 +
|Step_Content=<translate>Connect feed pipes from energy chain to supply Y fittings</translate>
 +
|Step_Picture_00=R0015027_Install_Pneumatic_Connection_rail_and_Air_Feeds_Screenshot_2023-10-30_110404.png
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Add P0000551 Quick exhaust valves</translate>
 +
|Step_Content=<translate>Add 3 off per side P0000551 qev valves to feed pipes</translate>
 +
|Step_Picture_00=R0015027_Install_Pneumatic_Connection_rail_and_Air_Feeds_Screenshot_2023-10-30_110404.png
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Connect cylinder rail 1 pipe loom</translate>
 +
|Step_Content=<translate>Connect cylinder rail 1 pipe loom to connection rail</translate>
 +
|Step_Picture_00=R0015027_Install_Pneumatic_Connection_rail_and_Air_Feeds_Screenshot_2023-10-30_110602.png
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Connect cylinder rail 2 pipe loom</translate>
 +
|Step_Content=<translate>Connect cylinder rail 2 pipe loom to connection rail</translate>
 +
|Step_Picture_00=R0015027_Install_Pneumatic_Connection_rail_and_Air_Feeds_Screenshot_2023-10-30_110602.png
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Connect cylinder rail 3 pipe loom</translate>
 +
|Step_Content=<translate>Connect cylinder rail 3 pipe loom to connection rail</translate>
 +
|Step_Picture_00=R0015027_Install_Pneumatic_Connection_rail_and_Air_Feeds_Screenshot_2023-10-30_110602.png
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Connect cylinder rail 4 pipe loom</translate>
 +
|Step_Content=<translate>Connect cylinder rail 4 pipe loom to connection rail</translate>
 +
|Step_Picture_00=R0015027_Install_Pneumatic_Connection_rail_and_Air_Feeds_Screenshot_2023-10-30_110602.png
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Connect cylinder rail 5 pipe loom</translate>
 +
|Step_Content=<translate>Connect cylinder rail 5 pipe loom to connection rail</translate>
 +
|Step_Picture_00=R0015027_Install_Pneumatic_Connection_rail_and_Air_Feeds_Screenshot_2023-10-30_110602.png
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Connect cylinder rail 6 pipe loom</translate>
 +
|Step_Content=<translate>Connect cylinder rail 6 pipe loom to connection rail</translate>
 +
|Step_Picture_00=R0015027_Install_Pneumatic_Connection_rail_and_Air_Feeds_Screenshot_2023-10-30_110602.png
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Connect cylinder rail 7 pipe loom</translate>
 +
|Step_Content=<translate>Connect cylinder rail 7 pipe loom to connection rail</translate>
 +
|Step_Picture_00=R0015027_Install_Pneumatic_Connection_rail_and_Air_Feeds_Screenshot_2023-10-30_110602.png
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Connect cylinder rail 8 pipe loom</translate>
 +
|Step_Content=<translate>Connect cylinder rail 8 pipe loom to connection rail</translate>
 +
|Step_Picture_00=R0015027_Install_Pneumatic_Connection_rail_and_Air_Feeds_Screenshot_2023-10-30_110602.png
 
}}
 
}}
 
{{Notes}}
 
{{Notes}}
 
{{PageLang
 
{{PageLang
 +
|Language=en
 
|SourceLanguage=none
 
|SourceLanguage=none
 
|IsTranslation=0
 
|IsTranslation=0
|Language=en
 
 
}}
 
}}
 
{{Tuto Status
 
{{Tuto Status
 
|Complete=Draft
 
|Complete=Draft
 
}}
 
}}

Version du 30 octobre 2023 à 13:08

Auteur avatarGareth Green | Dernière modification 4/12/2023 par Gareth Green en cours de rédaction

Introduction

Tools Required


Standard hex key set

Pipe cutters

Standard spanner set


Parts Required


D0015578 Energy Chain Bracket - Moving x 2

P0000551 6mm inline Quick Exhaust Fitting x 6

P0000046 6mm y fitting x 6

R0015289 Bench assemble pipe connection rail




Étape 1 - Unless otherwise stated

Use Loctite 243 on all fasteners

Use Loctite 572 on all threaded pneumatic connection

Pen mark all fasteners to show finalised



Étape 2 - Fit connection rail

Fit pre assembled connection rail



Étape 3 - Add energy chain mounting brackets

Fit energy chain mounting brackets to cylinder rails



Étape 4 - Connect energy chains from modules

Connect fitted energy chains from modules C and E to brackets



Étape 5 - Add Y connections

Break into feed lines on cylinder rails with 6mm y fittings



Étape 6 - Connect Feed pipes

Connect feed pipes from energy chain to supply Y fittings



Étape 7 - Add P0000551 Quick exhaust valves

Add 3 off per side P0000551 qev valves to feed pipes



Étape 8 - Connect cylinder rail 1 pipe loom

Connect cylinder rail 1 pipe loom to connection rail



Étape 9 - Connect cylinder rail 2 pipe loom

Connect cylinder rail 2 pipe loom to connection rail



Étape 10 - Connect cylinder rail 3 pipe loom

Connect cylinder rail 3 pipe loom to connection rail



Étape 11 - Connect cylinder rail 4 pipe loom

Connect cylinder rail 4 pipe loom to connection rail



Étape 12 - Connect cylinder rail 5 pipe loom

Connect cylinder rail 5 pipe loom to connection rail



Étape 13 - Connect cylinder rail 6 pipe loom

Connect cylinder rail 6 pipe loom to connection rail



Étape 14 - Connect cylinder rail 7 pipe loom

Connect cylinder rail 7 pipe loom to connection rail



Étape 15 - Connect cylinder rail 8 pipe loom

Connect cylinder rail 8 pipe loom to connection rail



Commentaires