[version en cours de rédaction] | [version en cours de rédaction] |
Ligne 58 : | Ligne 58 : | ||
{{Tuto Step | {{Tuto Step | ||
|Step_Title=<translate>Regenerate Projects</translate> | |Step_Title=<translate>Regenerate Projects</translate> | ||
− | |Step_Content=<translate># Put old projects into a clearly named folder | + | |Step_Content=<translate>#Put old projects into a clearly named folder |
− | # Create | + | #Create a new empty folder with the name of the machine. |
− | # Open Project | + | #Open Project "From Target" to the new folder |
− | # Check the | + | #Check the mappings are present |
− | # Add a Drive Manager project</translate> | + | #Add a Drive Manager project</translate> |
}} | }} | ||
{{Tuto Step | {{Tuto Step | ||
Ligne 79 : | Ligne 79 : | ||
− | If you have an old drive | + | If you have an old drive manager you may have to enter: |
− | The value may be in .1 scale hence factor | + | The value may be in .1 scale hence factor of 10 and also could be in HEX |
120 or 0C00, | 120 or 0C00, | ||
Ligne 102 : | Ligne 102 : | ||
{{Tuto Step | {{Tuto Step | ||
|Step_Title=<translate>For Both Drives</translate> | |Step_Title=<translate>For Both Drives</translate> | ||
− | |Step_Content=<translate># Add to startup | + | |Step_Content=<translate>#Add to startup parameters |
− | # Download to drive | + | #Download to drive |
− | # Save project | + | #Save project |
− | # Activate | + | #Activate |
− | # Update control | + | #Update control board</translate> |
}} | }} | ||
{{Tuto Step | {{Tuto Step |
For the ZX machines that have a servo motor rather than a piston to rotate the Saw the Torque needs to be reduced significantly
Auteur Gareth Green | Dernière modification 15/03/2023 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
For the ZX machines that have a servo motor rather than a piston to rotate the Saw the Torque needs to be reduced significantly
SR Axis, Torque SR_Axis_Torque_Adjustment_TorqueCrib.png
Check Axis.mul and look at the line
SR,7,1,1,291833.500,1,200,500,500,125.1,90.0,InF_SRHome,3,20,5,0.0,5.0,10.0,0.000,
Gear ratio
291833.500 100:1
145602.000 50:1
AX8206 Drive
or
AX5003 Drive
It should be a AM8032-E
The AM8032-E has torque constant of 0.8 N/A
We are aiming to deliver a torque of no more than 56 Nm
For
100:1 the motors maximum delivered torque 0.56 Nm
or
50:1 the motors maximum delivered torque 1.12 Nm
Use drive manager to get to the parameters.
Check the value of P-0-092 this value should be 5.9A (if not seek help)
Change the value of S-0-0092 to
12% for 100:1
or
24% for 50:1
If you have an old drive manager you may have to enter:
The value may be in .1 scale hence factor of 10 and also could be in HEX
120 or 0C00,
240 or F000
Check channel B 0x3643:1 s/b 2.95A
Change 0x6872 to
24% for 100:1
or
48% for 50:1