R0015251B Bench Assemble X Axis Energy chain : Différence entre versions

[version en cours de rédaction][version en cours de rédaction]
 
Ligne 5 : Ligne 5 :
 
|Categories=Production
 
|Categories=Production
 
|Difficulty=Medium
 
|Difficulty=Medium
|Duration=1.5
+
|Duration=2
 
|Duration-type=hour(s)
 
|Duration-type=hour(s)
 
}}
 
}}

Version actuelle datée du 3 avril 2024 à 11:24

Auteur avatarGareth Green | Dernière modification 3/04/2024 par Gareth Green en cours de rédaction

Introduction

Tools Required


Small flat screwdriver

Identification markers


Parts Required


A0001112 Energy Chain Separator: 2500 Chain x 24

A0001113 Energy Chain: Series 2500.03 55mm Bend Radius x 4.2 meter

A0001114 Energy Chain Bracket Set: 24/2500 Plastic, Pivoting x 1

E0000439 Connector Brad Harrison M8 3 pole 10 m lead pvc x 3

E0001237 Pre Made Cable :Beckoff Extension AM8032 9.0m x 1


Étape 1 - Count links

Total links of for A0001113 Energy Chain is 113


Double check correct quantity, But do not assemble links yet



Étape 2 - Assemble links and reverse 2 off

1 Assemble 111 links together , ensure all links are orientated the same way .


2 Identify the female end of the assembled links


3 Fit 2 more links of A0001113, but fit in a reversed orientation


Étape 3 - Attach mounting brackets

Attach mounting brackets A0001114


1 Attach male bracket to reversed links and orientated as shown


2 Attach female bracket to opposite end orientated as shown

3 Energy ends will now be itemised as A and B as shown


Étape 4 - Fit separators

1 Open all links of trunking using a small flat screwdriver to release

Picture required please :)


2 Fit A0001112 Energy Chain Separators to the following positions


Start From reversed link end A , fit 2 separators to first reversed link

3 Counting from the first separators fitted, fit additional 2 off separators to every tenth link

4 This is correct

Étape 5 - Fit E0000439 Cables

Add identification markers to 3 off E0000439 cables


X44

X283

X10


Fit cables to energy chain in section 1 as shown. Plugs should exit energy chain at the male bracket / reversed link end . Leave 360mm from end of energy chain to the end of the female plugs.


Étape 6 - Fit E0001237 servo cable

Use Cable E0001237 Pre Made Cable :Beckoff Extension AM8032 9.0m x 1 and identify as 'XA'


Fit to section 2 and leave Female plug and 0.5meter of cable to exit energy chain at end A


Étape 7 - Fit air pipes

Cut 3 0ff lengths of 6mm x 4mm black air pipe at 9 meters


Add identification as follows


1229

1211

1219


Fit to section 3 and leave 1 meter of pipe exiting the energy chain at end A


Commentaires

Draft