R0015307 Bench assembly spindle drive cylinders : Différence entre versions

[version en cours de rédaction][version en cours de rédaction]
Ligne 121 : Ligne 121 :
  
  
1  Attach P0000459 4mm elbom
+
1  Attach P0000459 4mm elbow
  
 
2 Attach P0001098 elbow
 
2 Attach P0001098 elbow
  
3 Attach P0001198 flow regulator elbow</translate>
+
3 Attach P0001202 flow regulator elbow</translate>
 
|Step_Picture_00=Bench_assembly_spindle_drive_cylinders_Screenshot_42.png
 
|Step_Picture_00=Bench_assembly_spindle_drive_cylinders_Screenshot_42.png
 
|Step_Picture_01=Bench_assembly_spindle_drive_cylinders_Screenshot_43.png
 
|Step_Picture_01=Bench_assembly_spindle_drive_cylinders_Screenshot_43.png

Version du 16 août 2023 à 15:12

Auteur avatarGareth Green | Dernière modification 11/12/2023 par Gareth Green en cours de rédaction

Introduction

Tools Required


Standard spanner set

Small screwdriver set

Reed switch test box

Araldite 2 part adhesive


Parts Required


D0015540 sensor bracket x 8

P0000488 Sensor x 8

P0001098 elbow adapter x 12

P0000238 6mm elbow x 8

P0001198 6mm flow elbow x 8

P0000459 4mm elbow x 4

P0001202 4mm flow elbow x 4

P0001200 cylinder x 8

P0001201 cylinder x 4

P0001047 reed switch x 16

D0007630 cylinder anchor x 8

M0001170 magnet x 8


Étape 1 - Unless otherwise stated

Loctite 243 must be used on all bolts

Bolts must be pen marked when finalised



Étape 2 - Mount single plunge home sensor

8 off

1 Remove OEM sensor locking nut from sensors P0000488

2 Label sensors at trailing end SH

3 Use m4 x 6 button heads and attach sensor to D0015540 as shown



Étape 3 - Attach air fittings to single plunge cylinders

8 off P0001200 cylinder


Use Loctite 572 on all air fittings


1 Attach P0001098 elbow as shown

2 Attach P0001198 elbow

3 Attach P0000238 elbow



Étape 4 - Attach sensor bracket to Single plunge cylider

8 off


Use 2 off m6 x 16 socket caps to attach sensor bracket to cylinder



Étape 5 - Fit single out sensor

8 off


1 label 8 off P0001047 sensor SO at connection end

2 Use test box and connect sensor and set position on cylinder with piston extended out of cylinder



Étape 6 - Attach air fittings to double plunge cylinders

Use Loctite 572 on all air fittings


4 off Cylinder P0001201


1 Attach P0000459 4mm elbow

2 Attach P0001098 elbow

3 Attach P0001202 flow regulator elbow


Étape 7 - Mount double plunge cylinder sensors

Mark 4 off sensors P0001047 at connection end DO

Mark 4 off sensors P0001047 at connection end DH


Use test box and set reed switches in position on cylinders orientated as shown in picture



Étape 8 - Mount magnet to cylinder anchor

M0001170 magnet must have additional adhesive applied to be adequately attached to D0007630 cylinder anchor



Commentaires

Draft