#Delete the setup zip file and unzipped directory to save hard drive space
#Delete the setup zip file and unzipped directory to save hard drive space
−
<br />{{Info|..."Specified account already exists" error will happen if the Visual Studio 2013 is not fully uninstalled and PC restarted}}<br /></translate>
+
<br />{{Info|..."Specified account already exists" error will happen if the Visual Studio 2013 or Beckhoff TwinCAT is not fully uninstalled and PC restarted. Use Revo uninstaller to completely remove it}}<br /></translate>
...Beckhoff Technical help is available on 01491 410539 option 3
Étape 1 - Install Visual Studio (if required)
...This now applies to all installations.
The "CNC" standard PCs used for the front end on Flowlines and ZXs have Visual Studio already installed but the TwinCAt version needs to be upgraded from 4022 to 4024
Uninstall all references to Visual Studio 2013 and Beckhoff Twincat3. If this is needed, restart the PC
Copy the install file from g:\Design\TwinCAT3\TC31-Full-Setup.3.1.4024.7.exe to the desktop of the Beckhoff PC
Run the install as Administrator
Delete the setup zip file and unzipped directory to save hard drive space
..."Specified account already exists" error will happen if the Visual Studio 2013 or Beckhoff TwinCAT is not fully uninstalled and PC restarted. Use Revo uninstaller to completely remove it
Étape 2 - Add the latest Device Description Table
Copy the contents of g:\design\twincat3\Beckhoff_EtherCAT_XML.zip
to
C:\TwinCAT\3.1\config\Io\EtherCAT and overwrite all the .xml files in this folder
...This allows the Beckhoff system to identify the latest version of the AX8000 drives
Étape 3 - Add Drive Manager 2 for AX8000 drives (if not installed already)
...This step needs to be done for the AX8000 drives only
Copy the Drive Manager 2 setup g:\design\TwinCAT3\TE5950-TC3-Drive-Manager-2.zip to Install Files or the desktop on the PC running Visual Studio
Close Visual Studio if it is open
Extract the Zip File
Run the Setup File
Delete the setup zip file and unzipped directory to save hard drive space
...Make sure you select the correct channel number / letter is it is a dual drive
Étape 22 - Add PLC_Reset to tc3Multi Link
...An output from tcMulti needs to be set up to an input on PLC reset to allow the PLC to reset itself. This is linke a physical wire between two PLCs but just exists in the software
Expand PLC_Reset Instance to get to ibResetPLC
Double Click ibResetPLC to open the properties
Link to qbResetPLC (this is very far down the list)