[version en cours de rédaction] | [version en cours de rédaction] |
(Page créée avec « {{Tuto Details |Description=<translate>Upgrading to winMulti v6</translate> |Categories=Software |Difficulty=Medium |Duration=30 |Duration-type=minute(s) |Tags=TB0385, Win... ») |
|||
Ligne 45 : | Ligne 45 : | ||
}} | }} | ||
{{Tuto Step | {{Tuto Step | ||
− | |Step_Title=<translate> | + | |Step_Title=<translate>Blank out the contents of PLC project folder c:\TwinCAT\[buildNo]\ tc3Multi_6_24</translate> |
|Step_Content=<translate></translate> | |Step_Content=<translate></translate> | ||
}} | }} | ||
{{Tuto Step | {{Tuto Step | ||
− | |Step_Title=<translate> | + | |Step_Title=<translate>Blank out the contents of PLC project folder c:\TwinCAT\[buildNo]\ PLC_Reset_1_1</translate> |
|Step_Content=<translate></translate> | |Step_Content=<translate></translate> | ||
}} | }} | ||
Ligne 61 : | Ligne 61 : | ||
}} | }} | ||
{{Tuto Step | {{Tuto Step | ||
− | |Step_Title=<translate> | + | |Step_Title=<translate>Ensure backend TwinCAT install is complete, which should end in a PC reboot</translate> |
|Step_Content=<translate></translate> | |Step_Content=<translate></translate> | ||
}} | }} | ||
Ligne 141 : | Ligne 141 : | ||
}} | }} | ||
{{Tuto Step | {{Tuto Step | ||
− | |Step_Title=<translate> | + | |Step_Title=<translate>WIDTH SENSOR SETUP</translate> |
|Step_Content=<translate></translate> | |Step_Content=<translate></translate> | ||
}} | }} | ||
Ligne 182 : | Ligne 182 : | ||
{{Notes}} | {{Notes}} | ||
{{PageLang | {{PageLang | ||
+ | |Language=en | ||
|SourceLanguage=none | |SourceLanguage=none | ||
|IsTranslation=0 | |IsTranslation=0 | ||
− | |||
}} | }} | ||
{{Tuto Status | {{Tuto Status | ||
|Complete=Draft | |Complete=Draft | ||
}} | }} |
Upgrading to winMulti v6
Auteur Gareth Green | Dernière modification 5/01/2023 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Pas encore d'image
Upgrading to winMulti v6
TB0385, WinMulti, v6
Run VS, download from archive save in folder c:\TwinCAT\[BuildNo] (create folder if not there)
Update TwinCAT on Backend PC using file g:\Design\TwinCAT3\ TC31-XAR-Setup.3.1.4022.2.exe
(create folder if not there)
File transfer from g:\design\TwinCAT3\Lab v6\tc3Multi_6_24 to c:\twincat\stuga\[BuildNo]\tcMulti_6_24
File transfer from g:\design\TwinCAT3\Lab v6\PLC_Reset_1_1 to c:\twincat\stuga\[BuildNo]\ PLC_Reset_1_1
The new versions of tc3Multi should be there – check the POUs->Version Info (PRG) to ensure it is a new version
(Defaults to Config mode after the TwinCAT update)
(axis->Settings tab Link to PLC button)
(axis->Settings tab Link to PLC button)
(field at end of line, NOT the id number at start)
Check the EtherCAT devices - May need a reload devices if the devices cannot see the fieldbus boxes
Check that the emergency stop InS_Estop when reset gives a high input into the IO screen
Only need to update the ones that are ticked
It is not an alarm and will stop transfer table if opened
The voltage input is displayed in the “Value” column and should read a low value when clamp is open and above 32000 when clamp closed (CLIS output on)
This is iAnalogueInputArray[0].
a. widthMeasureOffset=132.8
b. widthMeasureScale=-0.0030469 <- Note the minus at the beginning
c. widthMeasuringMode=1
Calibrate the widthMeasureOffset by using CLIS to measure some known profile widths. The measure result can be seen on frmService->Clear Blockages Tab
Ensure all profiles with a rebate where CLIS will go underneath have the rebate distance correctly set up in the profile settings. This is all Z profiles. These can be set from the Settings->Profiles Tab
Ps_sideClamp is used now as the delay for the side clamp before checking the width – this may need to be increased to allow side clamp to close on narrow profiles
If all fails, width measuring can be switched off with widthMeasuringMode=0