[version en cours de rédaction] | [version en cours de rédaction] |
(20 révisions intermédiaires par 2 utilisateurs non affichées) | |||
Ligne 129 : | Ligne 129 : | ||
| | | | ||
|OuA_GripTurn | |OuA_GripTurn | ||
− | |Sturtz Infeed Grip Turn Cylinder Up | + | OuA_Turn90 |
+ | |Sturtz Infeed Grip Turn Cylinder Up to 90 degrees | ||
|- | |- | ||
|22 | |22 | ||
Ligne 345 : | Ligne 346 : | ||
|OuB_Oiler | |OuB_Oiler | ||
| | | | ||
+ | |- | ||
+ | |79 | ||
+ | | | ||
+ | |OuF_LowerEj | ||
+ | |Lower eject system on Autoflow Mk4 | ||
|- | |- | ||
|80 | |80 | ||
| | | | ||
|OuF_ClampIT | |OuF_ClampIT | ||
− | | | + | OuF_ITHigh |
+ | |If the clamp on the saw infeed top is a roller clamp, use this output to activate a high pressure 3/2 valve | ||
|- | |- | ||
|81 | |81 | ||
Ligne 389 : | Ligne 396 : | ||
Soenen Eject Push to Conveyor A | Soenen Eject Push to Conveyor A | ||
+ | |- | ||
+ | |88 | ||
+ | | | ||
+ | |OuF_EjOutfeed | ||
+ | |Autoflow Mk4 Eject Back to Back Cylinder Outfeed Side | ||
+ | |- | ||
+ | |89 | ||
+ | | | ||
+ | |OuF_ClampPad | ||
+ | |Static Clamp Pad for Autoflow Mk4 | ||
|- | |- | ||
|90 | |90 | ||
Ligne 394 : | Ligne 411 : | ||
|OuF_Conveyor | |OuF_Conveyor | ||
| | | | ||
− | |||
|- | |- | ||
Ligne 464 : | Ligne 480 : | ||
|104 | |104 | ||
| | | | ||
− | | | + | |OuF_ConvYAFwd |
− | |Soenen Conveyor Direction Y Position A (next to M/c) | + | |Soenen Conveyor Direction Y Position A (next to M/c) FORWARD |
|- | |- | ||
|105 | |105 | ||
| | | | ||
− | | | + | |OuF_ConvYARev |
− | | | + | |Soenen Conveyor Direction Y Position A (next to M/c) REVERSE |
|- | |- | ||
|106 | |106 | ||
| | | | ||
− | | | + | |OuF_EjectInfeed |
− | | | + | |Autoflow Mk4 Eject Back to Back Cylinder Infeed Side |
|- | |- | ||
|107 | |107 | ||
Ligne 506 : | Ligne 522 : | ||
|OuA_WheRev | |OuA_WheRev | ||
| | | | ||
+ | |- | ||
+ | |113 | ||
+ | | | ||
+ | |OuA_ConvSlow | ||
+ | |Autoflow Mk4 Output for Infeed Conveyor Slow Speed | ||
+ | |- | ||
+ | |114 | ||
+ | | | ||
+ | |OuG_ConvSlow | ||
+ | |Autoflow Mk4 Output for Outfeed Conveyor Slow Speed | ||
|- | |- | ||
|121 | |121 | ||
Ligne 746 : | Ligne 772 : | ||
|OuF_ZsupportO | |OuF_ZsupportO | ||
|Z Support Cylinder Outfeed Side on ZX5 only | |Z Support Cylinder Outfeed Side on ZX5 only | ||
+ | |- | ||
+ | |226 | ||
+ | | | ||
+ | |OuE_ChanLow | ||
+ | |Low pressure output for channel bar | ||
|- | |- | ||
|227 | |227 | ||
Ligne 881 : | Ligne 912 : | ||
| | | | ||
|OuA_TurnUp | |OuA_TurnUp | ||
− | |Sturtz Infeed Grip Turn Cylinder | + | OuA_Turn0 |
− | + | |Sturtz Infeed Grip Turn Cylinder Down (0 degrees standard) | |
|- | |- | ||
|259 | |259 | ||
Ligne 947 : | Ligne 978 : | ||
| | | | ||
|OuB_InvDP | |OuB_InvDP | ||
− | | | + | |Inverter Double Plunge output |
+ | |||
+ | Signals an inverter that double output power is needed. | ||
+ | {{Info|...This needs to be seperate from a simple plunge signal because the inverter needs the command and a changeover delay before the accelleration command}} | ||
+ | Also referred as 316 on TwinCAT2 machines | ||
|- | |- | ||
|272 | |272 | ||
Ligne 1 001 : | Ligne 1 036 : | ||
|282 | |282 | ||
|Y282 | |Y282 | ||
− | | | + | |OuF_ConvYBFwd |
− | |Soenen Conveyor Direction Y Position B | + | |Soenen Conveyor Direction Y Position B FORWARD |
|- | |- | ||
− | | | + | |283 |
− | | | + | |Y283 |
− | | | + | |OuF_ConvYBRev |
− | | | + | |Soenen Conveyor Direction Y Position B REVERSE |
+ | |- | ||
+ | |284 | ||
+ | |Y284 | ||
+ | |OuB_VibPlate | ||
+ | |Autoflow Mk4 Vibration Plate | ||
+ | |- | ||
+ | |285 | ||
+ | |Y285 | ||
+ | |OuB_TopSpinBlow | ||
+ | |Working Spindle Blower on ZX5 | ||
|- | |- | ||
| | | | ||
Ligne 1 029 : | Ligne 1 074 : | ||
| | | | ||
|- | |- | ||
− | + | |290 | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |290 | ||
|Y290 | |Y290 | ||
|OuF_CLHClose | |OuF_CLHClose | ||
Ligne 1 079 : | Ligne 1 114 : | ||
| | | | ||
|- | |- | ||
+ | |302 | ||
| | | | ||
+ | |OuB_SP1R2 | ||
+ | |Spindle 1 Control Relay 2 Select | ||
+ | |- | ||
+ | |303 | ||
| | | | ||
+ | |OuB_SP2R2 | ||
+ | |Spindle 2 Control Relay 2 Select | ||
+ | |- | ||
+ | |304 | ||
| | | | ||
+ | |OuB_SP3R2 | ||
+ | |Spindle 3 Control Relay 2 Select | ||
+ | |- | ||
+ | |305 | ||
| | | | ||
+ | |OuB_SP4R2 | ||
+ | |Spindle 4 Control Relay 2 Select | ||
|- | |- | ||
+ | |306 | ||
| | | | ||
+ | |OuB_SP5R2 | ||
+ | |Spindle 5 Control Relay 2 Select | ||
+ | |- | ||
+ | |307 | ||
| | | | ||
+ | |OuB_SP6R2 | ||
+ | |Spindle 6 Control Relay 2 Select | ||
+ | |- | ||
+ | |308 | ||
| | | | ||
+ | |OuB_SP7R2 | ||
+ | |Spindle 7 Control Relay 2 Select | ||
+ | |- | ||
+ | |309 | ||
| | | | ||
+ | |OuB_SP8R2 | ||
+ | |Spindle 8 Control Relay 2 Select | ||
+ | |- | ||
+ | |310 | ||
+ | |Y310 | ||
+ | |OuF_AABlw | ||
+ | |Label Area Blower | ||
+ | |- | ||
+ | |311 | ||
+ | |Y311 | ||
+ | |OuF_AAVac | ||
+ | |Vacuum Pump Valve (Label Applicator) | ||
+ | |- | ||
+ | |312 | ||
+ | |Y312 | ||
+ | |OuF_AATilt | ||
+ | |Applicator Tilt (Label Applicator) | ||
+ | |- | ||
+ | |313 | ||
+ | |Y313 | ||
+ | |OuF_AAPlace | ||
+ | |Applicator Place Up/Down (Label Applicator) | ||
+ | |- | ||
+ | |314 | ||
+ | |Y314 | ||
+ | |OuF_AAPick | ||
+ | |Applicator Pick (Yaxis) (Label Applicator) | ||
+ | |- | ||
+ | |315 | ||
+ | |Y315 | ||
+ | |OuF_AAPulse | ||
+ | |Label Applicator Profile Position Turret Pulse | ||
+ | |- | ||
+ | |316 | ||
+ | |Y316 | ||
+ | |Inv_DP | ||
+ | |Inverter Double plunge output used on TC2 machines | ||
+ | |||
+ | The standard should be Y271, but this refernce has crept in on TwinCAT2 machines only | ||
|- | |- | ||
| | | | ||
Ligne 1 099 : | Ligne 1 201 : | ||
| | | | ||
|- | |- | ||
+ | |319 | ||
| | | | ||
− | + | |Ou_IPullOff | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |Ou_IPullOff | ||
|Ecoline Infeed Pull Off | |Ecoline Infeed Pull Off | ||
|- | |- | ||
Ligne 1 243 : | Ligne 1 310 : | ||
|340 | |340 | ||
| | | | ||
+ | |OuB_SpOff1 | ||
+ | |Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #1 | ||
+ | |- | ||
+ | |341 | ||
+ | | | ||
+ | |OuB_SpOff2 | ||
+ | |Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #2 | ||
+ | |- | ||
+ | |342 | ||
+ | | | ||
+ | |OuB_SpOff3 | ||
+ | |Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #3 | ||
+ | |- | ||
+ | |343 | ||
| | | | ||
+ | |OuB_SpOff4 | ||
+ | |Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #4 | ||
+ | |- | ||
+ | |344 | ||
| | | | ||
+ | |OuB_SpOff5 | ||
+ | |Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #5 | ||
|- | |- | ||
− | | | + | |345 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
+ | |OuB_SpOff6 | ||
+ | |Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #6 | ||
|- | |- | ||
− | | | + | |346 |
− | |||
− | |||
| | | | ||
+ | |OuB_SpOff7 | ||
+ | |Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #7 | ||
|- | |- | ||
− | | | + | |347 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
+ | |OuB_SpOff8 | ||
+ | |Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #8 | ||
|- | |- | ||
|350 | |350 | ||
Ligne 1 334 : | Ligne 1 411 : | ||
|RY1 | |RY1 | ||
|SPIN1 | |SPIN1 | ||
− | | | + | |*Spindle 1 Control Relay 1 Select on ZX5 Twin Inverter System* |
|- | |- | ||
|363 | |363 | ||
|RY2 | |RY2 | ||
|SPIN2 | |SPIN2 | ||
− | | | + | |*Spindle 2 Control Relay 1 Select on ZX5 Twin Inverter System* |
|- | |- | ||
|364 | |364 | ||
|RY3 | |RY3 | ||
|SPIN3 | |SPIN3 | ||
− | | | + | |*Spindle 3 Control Relay 1 Select on ZX5 Twin Inverter System* |
|- | |- | ||
|365 | |365 | ||
|RY4 | |RY4 | ||
|SPIN4 | |SPIN4 | ||
− | | | + | |*Spindle 4 Control Relay 1 Select on ZX5 Twin Inverter System* |
|- | |- | ||
|366 | |366 | ||
|RY5 | |RY5 | ||
|SPIN5 | |SPIN5 | ||
− | | | + | |*Spindle 5 Control Relay 1 Select on ZX5 Twin Inverter System* |
|- | |- | ||
|367 | |367 | ||
|RY6 | |RY6 | ||
|SPIN6 | |SPIN6 | ||
− | | | + | |*Spindle 6 Control Relay 1 Select on ZX5 Twin Inverter System* |
|- | |- | ||
|368 | |368 | ||
| | | | ||
|SPIN7 | |SPIN7 | ||
− | | | + | |*Spindle 7 Control Relay 1 Select on ZX5 Twin Inverter System* |
|- | |- | ||
|369 | |369 | ||
| | | | ||
|SPIN8 | |SPIN8 | ||
− | | | + | |*Spindle 8 Control Relay 1 Select on ZX5 Twin Inverter System* |
|- | |- | ||
|370 | |370 | ||
Ligne 1 687 : | Ligne 1 764 : | ||
|SPBL8 | |SPBL8 | ||
|- | |- | ||
− | | | + | |433 |
| | | | ||
| | | |
List of output references used on Stuga Machines
Auteur Gareth Green | Dernière modification 19/11/2024 par Stuga Engineer en cours de rédaction ⧼frevu-button-review-label⧽
List of output references used on Stuga Machines
IORef, Outputs Stuga_Machine_IO_Dictionary_-_Outputs_Annotation_2020-04-14_111945.jpg
For input references see here
IORef | Legacy Wire Label | Code | Description |
---|---|---|---|
1 | Y25
OY2 |
Ou_GRIP
GRIP |
Gripper on flowlines |
Y001 | OuA_Grip | Gripper on Autoflow | |
3 | OuA_GripBlow | ||
4 | OuA_LoadBlow | ||
5 | OuA_PopUp | ||
6 | OuA_Dog0 | ||
7 | OuA_Dog1 | ||
8 | OuA_Dog2 | ||
9 | OuA_Dog3 | ||
10 | OuA_Dog4 | ||
11 | OuA_Dog5 | ||
12 | OuA_PopV9 | ||
13 | OuA_PopUpPush | ||
OuA_PopH1 | |||
14 | OuA_PopUp2 | ||
15 | OuA_PopUp3 | ||
16 | OuA_PopUp4 | ||
17 | OuA_PopUp5 | ||
18 | OuA_PopUp6 | ||
19 | OuA_PopUp7 | ||
20 | OuA_PopUp8 | ||
21 | OuA_GripTurn
OuA_Turn90 |
Sturtz Infeed Grip Turn Cylinder Up to 90 degrees | |
22 | OuA_StopX | ||
23 | OuA_InfeedAdv | ||
24 | OuA_BrakesOff | ||
25 | OuA_CillSupport | ||
26 | OuA_EDSpindleOn | ||
27 | OuA_EDClamp | ||
28 | OuA_EDPlunge | ||
29 | OuA_EDGuardOpen | ||
30 | OuB_ClampIT | ||
31 | OuB_ClampITPos | ||
32 | OuB_ClampIS | ||
33 | OuB_ClampISPos | ||
34 | OuB_ClampOT | ||
35 | OuB_ClampOTPos | ||
36 | OuB_ClampOS | ||
37 | OuB_ClampOSPos | ||
38 | OuB_Spin1Pl | ||
39 | OuB_Spin2Pl | ||
40 | OuB_Spin3Pl | ||
41 | OuB_Spin4Pl | ||
42 | OuB_Spin5Pl | ||
43 | OuB_Spin6Pl | ||
44 | OuB_Spin7Pl | ||
45 | OuB_Spin8Pl | ||
46 | OuB_Spin1On | ||
47 | OuB_Spin2On | ||
48 | OuB_Spin3On | ||
49 | OuB_Spin4On | ||
50 | OuB_Spin5On | ||
51 | OuB_Spin6On | ||
52 | OuB_Spin7On | ||
53 | OuB_Spin8On | ||
54 | OuB_Spin1DP | ||
55 | OuB_Spin2DP | ||
56 | OuB_Spin3DP | ||
57 | OuB_Spin4DP | ||
58 | OuB_Spin5DP | ||
59 | OuB_Spin6DP | ||
60 | OuB_Spin7DP | ||
61 | OuB_Spin8DP | ||
62 | OuB_SpinFwd | ||
63 | OuB_Spin300 | ||
64 | OuB_Oiler | ||
79 | OuF_LowerEj | Lower eject system on Autoflow Mk4 | |
80 | OuF_ClampIT
OuF_ITHigh |
If the clamp on the saw infeed top is a roller clamp, use this output to activate a high pressure 3/2 valve | |
81 | OuF_ClampITPos | ||
82 | OuF_ClampOT | ||
83 | OuF_ClampOTPos | ||
84 | OuF_ClampIS | ||
85 | OuF_ClampOS | ||
86 | OuF_ClampITRoll | ||
87 | OuF_EjectPush
OuF_EjPushA |
| |
88 | OuF_EjOutfeed | Autoflow Mk4 Eject Back to Back Cylinder Outfeed Side | |
89 | OuF_ClampPad | Static Clamp Pad for Autoflow Mk4 | |
90 | OuF_Conveyor | ||
91 | OuF_Eject | ||
92 | OuF_TiltSaw | ||
93 | OuF_OffcutBlow | ||
94 | OuF_Siren | ||
95 | OuF_Gate | ||
96 | OuF_TiltPos | ||
97 | OuF_SawOn | ||
98 | OuF_ExtractOn | ||
99 | OuF_ChuteBlow | ||
100 | OuA_Dog6 | ||
101 | OuA_Dog7 | ||
102 | OuA_Dog8 | ||
103 | OuF_SRBlw | Blower for SR Axis | |
104 | OuF_ConvYAFwd | Soenen Conveyor Direction Y Position A (next to M/c) FORWARD | |
105 | OuF_ConvYARev | Soenen Conveyor Direction Y Position A (next to M/c) REVERSE | |
106 | OuF_EjectInfeed | Autoflow Mk4 Eject Back to Back Cylinder Infeed Side | |
107 | OuA_Crank | Module A Crank | |
108 | OuA_DDrlMot | Datum Drill Motor | |
109 | OuA_ConvFwd | ||
110 | OuA_ConvRev | ||
111 | OuA_WheFwd | ||
112 | OuA_WheRev | ||
113 | OuA_ConvSlow | Autoflow Mk4 Output for Infeed Conveyor Slow Speed | |
114 | OuG_ConvSlow | Autoflow Mk4 Output for Outfeed Conveyor Slow Speed | |
121 | OuC_GripH | Module C Grip Height Home | |
122 | OuC_BlwRack | Module C Rack Blower | |
123 | OuC_BlwGrip | Module C Grip Blower | |
124 | OuC_Roller | Module C Roller Lift | |
125 | OuC_Chan1 | Module C Channel | |
126 | OuC_BeamPosH | GX Axis Beam Position Home | |
127 | OuC_BeamPosO | GX Axis Beam Position Out | |
128 | OuC_CrankFwd | Module C Crank | |
131 | OuE_GripH | Module E Grip Height | |
132 | OuE_Grip | Module E Grip | |
133 | OuE_BlwRail | Module E Blower for Loader linear rails | |
145 | OuE_BlwGrip | Module E Grip Blower | |
146 | OuE_Roller | Module E Roller Lift | |
150 | OuE_Backfence | Module E Backfence Roller Lift - Not used | |
151 | OuE_Crank | Module E Crank | |
152 | OuA_Chan1 | Module A Channel 1 | |
153 | OuA_Chan2 | Module A Channel 2 (Datum Drill) | |
154 | OuA_WheelH | Module A Wheel Height | |
155 | OuA_ChanLock | Module A Channel Lock | |
156 | OuA_DDrillPl | Datum Drill Plunge | |
157 | OuA_Roller | Module A Roller | |
158 | OuA_DDClamp | Datum Drill Clamp On | |
159 | OuC_GripLock | Gripper position lock Module C | |
160 | OuE_GripLock | Gripper position lock Module E | |
200 | OuF_GuardOpen | ||
201 | OuB_GuardOpen | ||
202 | OuF_ClampS | ||
203 | OuA_LoadClear | ||
204 | OuF_ClampPos | ||
206 | OuF_ClampCen | ||
207 | OuF_SawCut | ||
208 | OuF_Saw90 | ||
209 | OuF_Saw135 | ||
210 | OuF_ZsupportI | Z Support Cylinder (on ZX5 this is the infeed side) | |
211 | OuF_ClampSPos | ||
212 | OuF_ClampITHi | ||
213 | OuF_SawBlow | ||
214 | OuF_ZITurret | Z Turret Turn Infeed | |
215 | OuF_ZOTurret | Z Turret Turn Outfeed | |
216 | OuB_Red | MH Red Lamp | |
217 | OuB_Amber | MH Amber Lamp | |
218 | OuB_Green | MH Green Lamp | |
219 | OuF_RedSaw | Saw Red Lamp | |
220 | OuE_ChannelLock | ||
221 | OuE_ChannelPush | ||
222 | OuE_FlipZ | ||
223 | OuF_GreenSaw | Saw Green Lamp | |
224 | OuF_ZsupportO | Z Support Cylinder Outfeed Side on ZX5 only | |
226 | OuE_ChanLow | Low pressure output for channel bar | |
227 | OuE_SRSTSaw | Added by BB for Flowline with RS Auto/Beckhoff control | |
228 | OuE_TrMotor | ||
229 | OuE_TrDog1 | ||
230 | OuE_TrDog2 | ||
231 | OuE_TrDog3 | ||
232 | OuE_TrDog4 | ||
233 | OuE_TrDog5 | ||
234 | OuE_TrDog6 | ||
235 | OuE_TranUpDown | ||
236 | OuE_TranAcross | ||
237 | OuF_OffsetAH | ||
238 | OuE_BlwLens | ||
239 | OuE_BlwMLoad | Material load blower on Module E on ZX5 | |
240 | OuE_BlwHole | ||
241 | OuE_BlwRack | ||
242 | OuE_PushLift | ||
243 | OuB_BlwUR | ||
244 | OuC_BlwMLoad | Material Load Blower | |
250 | OuA_NextBar | ||
251 | OuA_VorBack | Sturtz Infeed Forward Carriage Back (Vorlaufwagen) | |
252 | OuA_VorFwd | Sturtz Infeed Forward Carriage Fwd | |
253 | OuA_VorUp | Sturtz Infeed Forward Carriage Clamp Up | |
254 | OuA_VorDn | Sturtz Infeed Forward Carriage Clamp Down | |
255 | OuA_GSGrip | Sturtz Infeed Grip Profile Short Grip (Shorter of the two cylinders) | |
256 | OuA_GSOff | Sturtz Infeed Grip Profile Short Open | |
257 | OuA_GLOff | Sturtz Infeed Grip Profile Long Open (longer of the two cylinders)
Output Ref 001 is used for the longer one as this is equivalent to grip output) | |
258 | OuA_TurnUp
OuA_Turn0 |
Sturtz Infeed Grip Turn Cylinder Down (0 degrees standard) | |
259 | OuA_LiftUp | Sturtz Infeed Roller Table Up | |
260 | OuA_LiftUDn | Sturtz Infeed Roller Table Down | |
261 | OuA_StopUp | Sturtz Infeed Paddle Stop Up | |
262 | OuA_StopDn | Sturtz Infeed Paddle Stop Down | |
263 | OuA_GRTRotate | Sturtz Infeed Guide Roller Turn Cylinder Rotate | |
264 | OuA_GRTOpen | Sturtz Infeed Guide Roller Turn Cylinder Initial | |
265 | OuA_GRHClamped | Sturtz Infeed Guide Roller Height Cylinder Clamp | |
266 | OuA_GRHOpen | Sturtz Infeed Guide Roller Height Cylinder Open | |
267 | OuA_InfeedLift | Profile lift clear of infeed belts | |
268 | OuA_SillLift | On Ancil saw, popup cylider to support profile | |
269 | OuB_BlwRing | ||
270 | OuB_CLIHold | ||
271 | OuB_InvDP | Inverter Double Plunge output
Signals an inverter that double output power is needed. ...This needs to be seperate from a simple plunge signal because the inverter needs the command and a changeover delay before the accelleration command
Also referred as 316 on TwinCAT2 machines | |
272 | OuC_BlwRail | ||
273 | OuC_CrankFwd | Module C Crank Motor Fwd - on reversing motor. Z067+ | |
274 | OuC_CrankRev | Module C Crank Motor Rev - on reversing motor Z067+ | |
275 | OuD_CrankFwd | Module D Crank Motor Fwd - on reversing motor Z067+ | |
276 | OuD_CrankRev | Module D Crank Motor Rev - on reversing motor Z067+ | |
277 | OuE_CrankFwd | Module E Crank Motor Fwd - on reversing motor Z067+ | |
278 | OuE_CrankRev | Module E Crank Motor Rev - on reversing motor Z067+ | |
279 | OuA_OpSiren | Operator Siren | |
280 | Y280 | OuF_ConvXA | Soenen Conveyor Direction X Position A (next to M/c) |
281 | Y281 | OuF_ConvXB | Soenen Conveyor Direction X Position B |
282 | Y282 | OuF_ConvYBFwd | Soenen Conveyor Direction Y Position B FORWARD |
283 | Y283 | OuF_ConvYBRev | Soenen Conveyor Direction Y Position B REVERSE |
284 | Y284 | OuB_VibPlate | Autoflow Mk4 Vibration Plate |
285 | Y285 | OuB_TopSpinBlow | Working Spindle Blower on ZX5 |
290 | Y290 | OuF_CLHClose | Sturtz Outfeed Horizontal Clamp Close |
291 | Y291 | OuF_CLHOpen | Sturtz Outfeed Horizontal Clamp Open |
292 | Y292 | OuF_LiftUp | Sturtz Outfeed Lift Station Up |
293 | Y293 | OuF_LiftDn | Sturtz Outfeed Lift Station Down |
294 | Y294 | OuF_OBarBlw | Sturtz Outfeed Bar Blower |
295 | Y295 | OuF_ConvFwd | Sturtz Outfeed Conveyor Forward |
296 | Y296 | OuF_ConvRev | Sturtz Outfeed Conveyor Reverse |
302 | OuB_SP1R2 | Spindle 1 Control Relay 2 Select | |
303 | OuB_SP2R2 | Spindle 2 Control Relay 2 Select | |
304 | OuB_SP3R2 | Spindle 3 Control Relay 2 Select | |
305 | OuB_SP4R2 | Spindle 4 Control Relay 2 Select | |
306 | OuB_SP5R2 | Spindle 5 Control Relay 2 Select | |
307 | OuB_SP6R2 | Spindle 6 Control Relay 2 Select | |
308 | OuB_SP7R2 | Spindle 7 Control Relay 2 Select | |
309 | OuB_SP8R2 | Spindle 8 Control Relay 2 Select | |
310 | Y310 | OuF_AABlw | Label Area Blower |
311 | Y311 | OuF_AAVac | Vacuum Pump Valve (Label Applicator) |
312 | Y312 | OuF_AATilt | Applicator Tilt (Label Applicator) |
313 | Y313 | OuF_AAPlace | Applicator Place Up/Down (Label Applicator) |
314 | Y314 | OuF_AAPick | Applicator Pick (Yaxis) (Label Applicator) |
315 | Y315 | OuF_AAPulse | Label Applicator Profile Position Turret Pulse |
316 | Y316 | Inv_DP | Inverter Double plunge output used on TC2 machines
The standard should be Y271, but this refernce has crept in on TwinCAT2 machines only |
319 | Ou_IPullOff | Ecoline Infeed Pull Off | |
320 | Ou_CLVHi | Ecoline V notch top clamp High pressure | |
321 | Y321 | Ou_EJPSH2
OuF_EjPushB |
Ecoline / Microline outfeed push 2
Soenen Eject Push to Conveyor B |
322 | Ou_VBLOW | Ecoline V Notch Blower | |
323 | Ou_IPULLO | Ecoline Infeed Pull Valve off (3 position valve) | |
324 | Ou_LENBLOW | Length sensor blower (not Used) | |
325 | Ou_VTURN | Ecoline V Front Turn | |
326 | Ou_WTURN | Ecoline V Rear Turn | |
327 | Ou_CLVO | Ecoline V Notch outfeed Side Clamp | |
328 | Ou_CLVI | Ecoline V Notch Infeed Side Clamp | |
329 | Ou_BcGrn | Ecoline Barcode Reader Green LED | |
330 | Ou_BcRed | Ecoline Barcode Reader Red LED | |
331 | Ou_BlwInfeed | Ecoline & Sturtz Infeed Blower | |
332 | |||
333 | OuA_PopUp1Off | Sturtz Infeed Push To Backfence 1 Open | |
334 | OuA_PopUp2Off | Sturtz Infeed Push To Backfence 2 Open | |
335 | OuA_PopUp3Off | Sturtz Infeed Push To Backfence 3 Open | |
336 | OuA_PopUp4Off | Sturtz Infeed Push To Backfence 4 Open | |
337 | OuA_PopUp5Off | Sturtz Infeed Push To Backfence 5 Open | |
338 | OuA_PopUp6Off | Sturtz Infeed Push To Backfence 6 Open | |
339 | OuA_PopUp7Off | Sturtz Infeed Push To Backfence 7 Open | |
340 | OuB_SpOff1 | Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #1 | |
341 | OuB_SpOff2 | Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #2 | |
342 | OuB_SpOff3 | Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #3 | |
343 | OuB_SpOff4 | Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #4 | |
344 | OuB_SpOff5 | Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #5 | |
345 | OuB_SpOff6 | Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #6 | |
346 | OuB_SpOff7 | Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #7 | |
347 | OuB_SpOff8 | Spindle Off relay - Turn spindle off on Beckhoff Quad Inverter System #8 | |
350 | Y1 | Ou_CLIT | |
351 | Y2 | Ou_CLIS | |
352 | Y3 | Ou_CLO | |
353 | Y4 | Ou_INDEX | Conveyor Motor |
354 | Y5 | Ou_CLUTC | |
355 | Y6 | Ou_STRAI | |
356 | Y7 | Ou_CLCL | ClampClamp hold - used on
Ecoline Flowline with DOS control |
357 | Y8 | Ou_ALIGN | |
358 | Y9
Y31 |
Ou_SMOT | |
359 | Y10 | Ou_MLOAD | Load Wheel / Roller Motor |
360 | Y11 | Ou_WBLOW | |
362 | RY1 | SPIN1 | *Spindle 1 Control Relay 1 Select on ZX5 Twin Inverter System* |
363 | RY2 | SPIN2 | *Spindle 2 Control Relay 1 Select on ZX5 Twin Inverter System* |
364 | RY3 | SPIN3 | *Spindle 3 Control Relay 1 Select on ZX5 Twin Inverter System* |
365 | RY4 | SPIN4 | *Spindle 4 Control Relay 1 Select on ZX5 Twin Inverter System* |
366 | RY5 | SPIN5 | *Spindle 5 Control Relay 1 Select on ZX5 Twin Inverter System* |
367 | RY6 | SPIN6 | *Spindle 6 Control Relay 1 Select on ZX5 Twin Inverter System* |
368 | SPIN7 | *Spindle 7 Control Relay 1 Select on ZX5 Twin Inverter System* | |
369 | SPIN8 | *Spindle 8 Control Relay 1 Select on ZX5 Twin Inverter System* | |
370 | OY1 | Ou_EJPSH | |
372 | OY3 | Ou_GRPSH | |
373 | OY4
Y27 Y373 |
Ou_OBLOW |
Sturtz Outfeed Sensor Blower |
374 | Ou_SRSTM/H | BB added M/H to description because we need to keep M/H and Saw side separate | |
375 | Y54 | Ou_OMBLW | Material Load Blower on Module A on Zx5 |
376 | SPDP3 | ||
377 | SPDP5 | ||
378 | Ou_ServoEnMH | Added by BB | |
379 | Ou_ServoEnSaw | Added by BB | |
380 | |||
381 | Y381 | OuF_ConvBrake | Outfeed Conveyor Motor Brake |
382 | Y382 | OuA_ConvBrake | Infeed Conveyor Motor Brake |
383 | Ou_CLOUO | Under roller on outfeed side of V notch assembly | |
384 | Y52 | Ou_IPULL | |
385 | Y53 | Ou_IGRIP | OuA_IGrip on ZX5 |
386 | OuB_CLOI | ||
387 | Ou_VMOT | ||
388 | Ou_WMOT | ||
389 | Y32 | Ou_VICUT | |
390 | Y33 | Ou_VOCUT | |
391 | Y36 | Ou_WICUT | |
392 | Y37 | Ou_WOCUT | |
393 | Y42 | Ou_CLOO | Roller clamps on far outfeed side of Machining centre |
394 | Y43 | Ou_CLOUI | Under roller on infeed side of V notch assembly |
395 | Y44 | Ou_CLV | Fixed V notch clamp (front). Used for top and side V clamps on ZX5 |
396 | Ou_CLW | Fixed V notch clamp (Rear) | |
397 | Y16 | SPPL1 | |
Ou_VOURO | Microline | ||
398 | Y17 | SPPL2 | |
Ou_BLOWC | Microline | ||
399 | Y18 | SPPL3 | |
Ou_BLOWD | Microline | ||
400 | Y19 | SPPL4 | |
Ou_OPEN | Microline | ||
401 | Y20 | SPPL5 | |
Ou_WASTE | Microline | ||
402 | Y21 | SPPL6 | |
Ou_SWMOT | Microline | ||
403 | Y22 | SPPL7 | |
Ou_SAWC | Microline | ||
404 | Y23 | SPPL8 | |
Ou_S90 | Microline | ||
405 | Ou_S135 | Microline | |
406 | Ou_CLSIV | Microline | |
407 | Ou_CLSIP | Microline | |
Microline see 418 | |||
409 | Ou_CLSOP | Microline | |
410 | Ou_CLSIH | Microline | |
411 | Ou_CLSOH | Microline | |
412 | Ou_EJPS2 | Microline | |
413 | Ou_RRBLW | Ring Rack Blower | |
414 | Ou_RREXT | Ring Rack Extractor | |
415 | Ou_IDLE | v3.67 Idle Beacon | |
416 | Ou_InvDP | Inverter Double Plunge Current Boost
also 271 | |
418 | Ou_CLSOV | Microline - M005 moved to this number because it did not work on 408 (608) | |
419 | Y419 | Ou_GripPulse | Pulse Output for grip height Somatec unit |
425 | Reserved | SPBL1 | Spindle blow outputs reserved due to SPPLn+28 in Spindle On code. See Monday item |
426 | Reserved | SPBL2 | |
427 | Reserved | SPBL3 | |
428 | Reserved | SPBL4 | |
429 | Reserved | SPBL5 | |
430 | Reserved | SPBL6 | |
431 | Reserved | SPBL7 | |
432 | Reserved | SPBL8 | |