Details for manual pneumatic output testing on module
Auteur Gareth Green | Dernière modification 2/04/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Details for manual pneumatic output testing on module
R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_135339.png
Tools Required
PCL airline connection
12mm blanking ports
Valve Manual over ride tool
Standard screwdriver set
Parts required
Output testing will require valve operation with no e/s circuit
Ensure the following
Work area is clear from all components not required for testing
All colleagues are aware of the procedure being undertaken
No additional colleagues are working on the module
PCL coupling is accessible to release pressure in case of emergency
Testing procedure is fully adhered to
Wind fully out soft start screw situated on top on main air service unit
Connect main pcl air feed to air service unit
Increase Air service unit pressure to 6.0bar /6mpa
Check for audible leaks on the red pipe lines installed and correct if found
Check air gun regulator functions properly . Fully open the regulator (2 bar limited ) and test air gun assembly