R0015333 Fit Clamp Assembly

Auteur avatarGareth Green | Dernière modification 27/02/2024 par Gareth Green en cours de rédaction

Introduction

Tools Required


Standard hex key set

Standard spanner set

1 meter straight edge

Feeler gauges

Soft hammer

Engineers square


Parts Required


R0015064 Bench Assemble Clamp Assy ZX5

Étape 1 - Unless otherwise stated

All bolts to have Loctite 243 adhesive applied unless otherwise stated

All Threaded Pneumatic connections to have Loctite 570 applied

All bolts to be pen marked once adhesive applied and correct tension added



Étape 2 - Attach Infeed clamp assembly

Attach infeed clamp assembly to infeed pad


Use 2 off M8 x 35 socket caps Do not use adhesive at this point

Étape 3 - Set position

Use soft hammer to adjust pillar position to be flush with cut table


Check position using engineers square as shown


Add final tension to M8 securing fasteners

Étape 4 - Fit outfeed clamp assembly

Fit outfeed clamp assembly to outfeed pad sing 2 off M8 x 50 socket caps and M8 motor plate washers

Do not use adhesive at this point

Étape 5 - Align clamps

Use 1 meter straight edge along pillars


Adjust OUTFEED CLAMP to set all 4 pillars to contact straight edge


Use feeler 0.002" /0.05mm gauge as maximum tolerance

Étape 6 - Finalise

Individually remove and apply adhesive to fasteners and apply final tension


Étape 7 - Recheck alignment

Recheck alignment once final tension is added to all fasteners


Check all clamps more freely up and down pillars when quip clamp has tension removed


Commentaires