R0015034B ZX5 Module B Wiring Loom installation Part 3

Auteur avatarGareth Green | Dernière modification 22/02/2024 par Gareth Green en cours de rédaction

Introduction

Parts Required


Pre labelled Wiring loom assembly R0015034B from electrical team


Tools required

Flush cutters

Tie wraps small

Tie Wraps Large

Étape 1 - Unless otherwise stated

All bolts to have Loctite 243 adhesive applied unless otherwise stated

All Threaded Pneumatic connections to have Loctite 570 applied

All bolts to be pen marked once adhesive applied and correct tension added



Étape 2 - Route Pre made 300hz connection

Route as shown power connection from wiring loom assembly


Z105 onwards as pictures

Z104 and below Different style plug mounted internally in trunking


Route cable to rear of machine as shown


Étape 3 - Handing guide

Please diagram to determine handing positions of machine sections

Étape 4 - Guard switches

Use pre wired guard switches from wiring loom box


CB45B Front interlock guard switch


Cb46B Rear interlock guard switch


Use diagram to determine position


Run cable to rear exits of machine


...Gaurd switches will be fixed into position at a later point



Étape 5 - Route Network cables

Route yellow and green network cables from loom box as shown


Cables route from Rear outfeed to rear infeed as shown .


Please clarify length of cable to be left extended from front or back of machine please


Étape 6 - Route 25way cable

Route 25way cable as shown. Route from Rear Infeed to Rear outfeed positions


Male plug to be positioned at Rear infeed position as shown



Étape 7 - V notch Motor Cables and VY Datum

Use cables


CB01B for connection to VI motor

CB02B for connection to VO motor

CB03B for connection to WI motor

CB04B for connection to WO motor


and already installed Cable x120


Motor identification should be determined by diagrams shown


Étape 8 - Route V notch motor cables and X120 1st energy chain

Route Cables as shown , to first energy chain , then through energy chain to exit point


Ensure cable retention points on energy chain brackets are used


Étape 9 - Route V notch motor cables, SY servo cable and X120 2nd energy chain

Use Servo cable identified V axis from wiring loom box, and incorporate with previous step cables to enter next energy chain .


Ensure cables are as shown and cable retention bracket is used to enable cables to be kept flat once fitted


Exit cables from top of energy chain


Étape 10 - Route V notch motor cables, SY servo cable and X120

Route 4 off green cables and x120 into trunking through 2 off 20mm grommit holes


Route servo cable as shown on cable tie bases


Ensure large cable base is fitted and used at indicated point


Exit cables at rear of machine


Étape 11 - Door Hinge safety cables

Use step 3 for correct identification of positions required


Use 4 off cables from wiring loom box


CB40B Front Infeed Hinge

CB41B Front Outfeed Hinge

CB42B Rear Infeed Hinge

CB43B Rear Outfeed Hinge


Ensure Tie base is used as shown , and star grommits are used for cable entry and exit through main frame work


All Cables to exit at rear of machine

Étape 12 - Camera Ring

Use cable from loom box labelled EN04B


Run from vertical trunking and exit cable at rear of machine




Étape 13 - Camera Infeed

Use cable from loom box labelled EN05B


Run from vertical trunking and exit cable at rear of machine



Étape 14 - Camera Outfeed

Use cable from loom box labelled EN06B


Always fitted same side of machine as previous 2 fitted camera cables


Run from vertical trunking and exit cable at rear of machine



Commentaires

Draft