Pneumatic connections and cable information
Auteur Gareth Green | Dernière modification 5/09/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Pneumatic connections and cable information
R0015324_Install_pipe_and_cable_looms_Screenshot_2023-08-31_113224.png
Tools Required
Standard hex key set
6mm black Air pipe
Pipe identification numbers
Pneumatic Pipe cutters
W0001002 cable (from consumable stock )
Parts Required
M0001127 Cable Tie Base (m6) (from consumable stock)
P0000046 Fitting: 'Y' Adaptor 6mm x 2
Use loctite 243 on all fasteners
Use Loctite 572 on all threaded pneumatic connections
Pen mark all bolts to show finalised
Attach 7 off M0001127 Cable Tie Base (m6) as shown using M5 x 10 button sockets
Identification numbers
951
959
1 Cut 2 6mm black air pipes long enough to run the indicated route
2 Identify each pipe, one 951 and one 959
3 Connect pipes to gate as indicated and leave pipes to loom later
Cut Length of W00010002 cable to follow the route shown , and mark both ends clearly Y94
Start to create loom from safety gate
Attach to first tiebase and separate pneumatic cables to top lug and cables to lower
Pipes 951 and 959, Y94 cable, and reed switches X189 and X190 should be loomed in as shown
Y94 should be left with enough length to connect to cut guard beacon when fitted
Cut 2 lengths of 6mm black airline at the right length to follow the indicated route
Pipe identifications
871 and 879
Connect pipes to indicated ports on cylinder
Continue looms bring in the two pipes and continue to the next push cylinder assembly
en none 0 Draft
Vous avez entré un nom de page invalide, avec un ou plusieurs caractères suivants :
< > @ ~ : * € £ ` + = / \ | [ ] { } ; ? #