Instructions for tool break assembly
Auteur Gareth Green | Dernière modification 21/08/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Instructions for tool break assembly
R0010260_Bench_Assemble_Tool_Break_Sensor_Screenshot_2023-07-18_144640.png
Tools Required
Standard tap set
Standard drill set
Standard hex key set
Pipe cutters
Flush cutters
Parts Required
A0001046 P Clip 6mm Steel / Rubber Liner
D0001962 Tool Sensor Mount
D0001963 Tool Sensor Post
D0001964 Tool Sensor Logo Plate
E0001120 Sensor: Ultrasonic M8 20-150mm
P0000046 Fitting: 'Y' Adaptor 6mm
P0000160 Fitting: Flow Controller In Line 6mm
P0000456 Compact straight male adapter 4mm- M5
Use Loctite 243 on all fasteners
Use Loctite 572 on all threaded pneumatic connection
Pen mark all fasteners to show finalised