R0015308 Bench assemble connection boxes

Auteur avatarGareth Green | Dernière modification 23/06/2023 par Gareth Green en cours de rédaction

Pre assembly of connection boxes for ring spindles

Introduction

Tools Required


Standard hex key set

3.3mm drill bit

Step drill

Drill

Small countersink


Parts Required


P0000439 Valve x 12

P0001092 4mm m7 fitting x 24

P0000455 valve lead x 12

P0000040 M7 6mm air fitting x 12

P0000036 M7 6mm elbow x 24

D0007618E connection box x 8

A0000152 blank x 16


Étape 1 - Assemble control valves

1 Assemble P0000439 valves as shown (12 off)

2 Ensure fittings have flats lined up for ease of installation

3 Attach P0000455 lead to valve (12 off)


Étape 2 - Check connection boxes and prepare cable entry

1 Check that connection boxes have had debris removed from coating process. Tap holes to clean if required . This applies to all tapped holes on the connection box

2 Fit 16 off A0000152 blanks to front section of connection box ( 2 per box)

3 Prepare 4 off boxes as shown in picture,using step drill for larger hole. Counter sink to tidy

4 Prepare 4 boxes as shown in picture, using step drill for larger hole. Counter sink to tidy

Commentaires

Draft