R0000712E Rotary Trunking

Auteur avatarGareth Green | Dernière modification 24/09/2024 par Gareth Green en cours de rédaction

Introduction

Tools Required

Étape 1 - Adhesive

All bolts must have Loctite 243 adhesive applied unless otherwise stated.


All bolts must be marked with pen once completed to indicate adhesive and correct tension has been applied



Étape 2 - Prepare 1st guide Section

D0003985 needs preparing before fitting


1 All back plates for the rotary trunking need to be checked for correct countersink depth. Any protrusion from main face will case energy chain failure

Check and if proud, use a countersink to increase depth


Étape 3 - Fit Energy chain mounting bracket

Mounting bracket D0006240 needs fitting to D0003985


1 Measure position of bracket onto circular guard (291mm)

2 Use a pointed m5 grubscrew screwed into bracket hole indicated, hold in position on guard, and use hide hammer to transfer position mark

3 Drill to 6mm and fix bracket with m5x 16 cap head and large m5 washer

4 Drill 6mm through indicated hole

5 Fix with M5 x 16 countersink, large m5 washer and nyloc nut

6 This countersink bolt head must be flush to block. If proud, use a countersink bit to increase depth


Étape 4 - Prepare second section

Check countersink holes in D0003930 are to the correct depth . Rework with countersink if fasteners sit proud.



Étape 5 - Prepare 3rd section

Check countersink holes in D0007817 are to the correct depth . Rework with countersink if fasteners sit proud.



Étape 6 - Fit D0007817

Mount D0007817 to main rotary base and fix with m5 x 10 countersink bolts



Étape 7 - Fit D0003930

Mount D0003930 to main rotary base and fix with m5 x 10 countersink bolts



Étape 8 - Fit D0003985

Mount D0003985 to main rotary base and fix with m5 x 10 countersink bolts



Étape 9 - Fit locking screw to energy chain

Drill and tap m3 to plugged end of energy chain assembly

Use m3 x 6 pan head bolt to secure


...Caution damage to cables is possible Use a shield over cables to protect



Étape 10 - Modify plug and mount echain bracket

1 Modify plug to allow cable and pipe clearance as shown

2 Modification is required to give access as indicated

3 Attach chain bracket with 2 off m5 x 10 button head and washers


Étape 11 - Mount bracket

1 Mount bracket D0001171 using 2 off m5 x 16 button heads and heavy washers

2 Captivate plug with m4 x 12 socket cap


Étape 12 - Finalise energy chain cables

1 ensure 600mm of green ethercat cable is set

2 ensure 6mm blue pipe is set to position

3 Ensure cable restraint is used once cable and pipe length are set ( M4 may need drilling )

Étape 13 - Fit Access panel

1 slide access panel into position

2 Fix energy chain to panel with m5 x 16 button heads, washers and nyloc nuts