The Jetter motor on the GZ axis has a brake. Releasing the brake without control could be harmful/dangerous.
Use the Air Counterbalance rig to assist if necessary.
This assumes that the motors are connected to the Beckhoff drive and are free to move.
Étape 1 - Initial Preparation
Ensure that the profile support arm is held out of the way to avoid marking the blue infeed arm.
Étape 2 - GY Axis:
Check that proximity arm is in between the proximity sensor.
You should be able to turn the leadscrew by hand to move it.
Do not move the GY axis if the counterbalance is active.
Étape 3 - GZ Axis
Check that proximity arm is in between the proximity sensor
This has a brake and you can only turn the leadscrew by hand if the counterbalance is fitted.
Étape 4 - Counterbalance
Counterbalance fitted under the carriage.
Adjust the pressure until you can turn the leadscrew of the GZ axis by hand. (6 bar)
Do not move the GY axis if the counterbalance is active
.
Étape 5 - CX5203 Firmware Upgrade
The firmware on the CX5203 must be high enough to be supported under Drive manager 2.
Because you have to remove and add drives back into a project, create a new project just to update the drives.
Expand I/O -> Devices-> Device (EtherCAT), Double click and open the Online tab.
Check the Drive you are going to update is in OP state and right mouse click on it.
Select FIRMWARE UP. Navigate to the location of the firmware. Normally C:\TwinCAT\Functions\TE5950-Drive-Manager-2\Firmware\AX5000
Do the same process for the EEROM matching the version number.
Check that you have the XML definition file for the version of firmware in C:\TwinCAT\3.1\Config\Io\EtherCAT\Beckhoff AX5xxx
With this done you should be able to delete the drives and add them back and check under drive manager 2
Étape 6 - Drive Manager 2 and Support Jetter Files
Ensure Drive Manager 2 is installed (Verion 1.1.60.0 minimum)
Copy the files from :
G:\Design\TwinCAT3\Other Motor Definition Files
GY Jetter JHN2-0028-18 SyncRot.dmmotor
GZ Jetter JHN2-0075-027 SyncRot.dmmotor
to C:\TwinCAT\Functions\TE5950-Drive-Manager-2\Database\Motors
Étape 7 - Basic Assumptions
The Motors are connected to an AX5203 Drive
GY on the A channel
GZ on the B channel
The Drive is labelled GY & GZ
The channels are mapped to AXIS with appropriate names
A Driver Manager 2 Project exisits with the Drives in it.
Étape 8 - GY setup Motor
Double click on GY axis (Ch A ) in drive manager 2 . You will not see the information highlighted yet.
For the Motor Press select then select the filter options.
Select Import.
Move to the folder C:\TwinCAT\Functions\TE5950-Drive-Manager-2\Database\Motors
Select the GY and Open
The parameters shold all mactch the screen shots.
Étape 9 - GY Setup FeedBack
From the Manager Scrren Press Select fo "Feedback 1"
Under filter Select as shown (Hiperface being the important one)
Expand Sick#SKx and select SKM36- HFA0-S05 and OK
Étape 10 - GY Setup Scaling
Select the Scaling Tab
Adjust the settings HightLighted.
When Checking the INVERT boes you will get a request to activate it straight away. Do not both as you have to activate all setting down later.
Before you save the NC Parameters Look at the values in red. If the new value is different to the Online value of the screen shot detick the is selected box so that it does not update.
Étape 11 - GY Setup Tuning
Select the Tune Drive tab
Set Kp = 0.02
Set Kp=85.2
Set Kv=25
Set Tn=3.0
Set Tn 0.8
...Whent entering the values type the number and pree Ctrl+Enter to save the value. If the value is RED then it has not been saved.
Étape 12 - GY Setup Commutation step 1 P-0-150
Select th Advance tab
Select Prameter List
In search Type P-0-150
Check the settings
You may have to change the Feedback direction to Negative
If you change it remeber to press download after the change
Expand the "Parameter chnannel"
Make sure that Commutation mode = Adjustable mechanical offset.
Make sure Adjust commutation offset (Mechanical) is 0.0 deg
Go to P-0-0057 Electrical commutation offset and set a value of 340 deg
Étape 13 - GY Setup Commutation angles(if necessary to change)
There are two forms of commutation set up Mechanical and Electrical.
Mechical is going to be 0 degrees and we are going to adjust the electrial using the command P-0-0166
Étape 14 - GZ Setup
Repeat as for GY with the following changes:
1) Motor Set up - select the GZ jetter file
2) Feedback set to Sick#SKS36-HFA0-S05 (Single turn...)
3) Brake paramters should be as pure image
4) Sccaling as per GY
5) Tune drive settings as per image.
6) Commutation P-0-150 as per Image
P-0-0057 Electrical commutation offset and set a value of 0 deg