Critical measurements and settings for an Autoflow infeed table


Method

...Make sure the GX axis is scaled correctly before starting any measurements
...Ensure the infeed is set at the correct distance from the machining centre (500mm between feet centreline


  • Use the gripper arm as the measuring stick. The datum must be set so that zero is the spindle centreline.
  • The measure point is when the gripper nose switch is depressed
Measurement Description A2027 Value Photo
Machining Centre to Infeed spacing DDistance between centrelines of feet 500
Zero Datum Centreline of spindles 0
measureStartPosX Measuring start position

Should be so that measure sensor is on machining centre side of the profile load fence

-880
infeedToZeroX Distance from zero to profile load fence 600
GX Axis Max position Maximum travel on GX Axis

After datum, press estop and manually move to end of travel

Note the value and subtract 10mm

7255
GX Move After Datum Ideally set to max profile length+infeedZeroToX+100
...Must not exceed GX Max pos


6500+600+100

=7200