Upgrade to machine control software to allow restart from Emergency Stop without reinitialise
Auteur Gareth Green | Dernière modification 14/03/2022 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Pas encore d'image
Upgrade to machine control software to allow restart from Emergency Stop without reinitialise
WinMulti, canSkipInitialise
Following estop, the software system has historically always required a full reinitialise including redatum. This is linked to the past where servo drive systems needed to be powered off on Estop, and had no means of saving the axis positions. It is also a great way of ensuring the system is completely reset properly.
The downside, however, is the amount of time it takes to reset. On machines such as the Autoflow , the bar has to be trimmed and replaced leading to wasted material.
Following the compliance review of 2022, more emergency stop related devices are needed - for example a light curtain across the infeed table on an autoflow. This means the system is far more likely to get triggered, and hence the time and profile wasted may increase to unacceptable levels
This has led to a new PLC software version (6.4) that will allow the restart of an Emergency stopped bar from where it has stopped. Front end (winMulti) software 6.4.96.0 is also required to provide the parameter
canSkipInitialise
If set to true, the restart from Estop process is different. Following the reset of the estop circuit (ES Reset button), the user is presented with 2 options
Depending on the machine type, and the situation the machine is in (ie running a bar, loading, unloading, etc) the user will be stepped through the process for restarting where the bar left off
en none 0