This feature allows the engineer to disable inputs through the front end. This has the following uses
If an eject home or out sensor is faulty, this can stop the machine from functioning. On v5 software, the operator could press escape to keep running. this feature is not available on v6 software. This update allows one or both of these sensors to be disabled and replaced with a timeout.
This is done through the IO Map setting screen:
The above screenshot shows the Eject push home input disabled and a timeout of 5000ms (5 seconds) used in place
On original saws before S092, the saw position at 135 and 45 degrees was fed via one input - Saw45. This meant that the saw135 input had to be physically wired into a different IO channel. the update allows this input to be disabled
This is done through the IO Map setting screen - tick the disable box for the Saw135 input:
If the input is not there, it need to be added in the ioDef file:
InF_Saw45,191,1,0,0,False,False,3,7,-,False,0,X14,False,-1
InF_Saw90,192,1,0,0,False,False,3,8,-,False,0,X24,False,-1
InF_Saw135,197,1,0,0,False,False,3,9,-,False,0,X197,False,-1
InF_Guard,196,1,0,0,False,False,0,3,-,False,0,X16,False,-1
OuF_Saw90,208,2,0,0,False,False,2,1,-,False,0,Y20,False,-1