Reference 010
Type Input
Code InA_GXHome, DATX
Description X axis home / datum input
Used On Autoflow Flowline / Microline / ZX3 / ZX4 Ecoline
Cable Marking X010 X7 X0
Function Provides a zero referencing point for the main X axis
Sensor Type Proximity Sensor Proximity Sensor Proximity Sensor
Adjustment Adjust distance to detected surface - should be <1mm
See Also
Picture
Input Definition 007 - InA GYHome Annotation 2020-04-16 164106.jpg
X Axis Datum Sensor.jpg