Common Issue - V Notching Too Close To End Of Bar

Auteur avatarGareth Green | Dernière modification 16/03/2020 par Gareth Green en cours de rédaction

Problems generated if V notch is to close to end of bar

Start Of Bar (Gripper End)

If the optimiser places a bar with a V notch close to the end at the gripper end of the bar, it can have detrimental effects

Common Issue - V Notching Too Close To End Of Bar Image.png


Modifications can be made to persuade the optimiser to move this piece to a different point on the bar

Machine Limit Photo Effect Solution
ZX3 / Microline / Flowline Mk3 <300mm
Common Issue - V Notching Too Close To End Of Bar IMG 20200316 114029 resized 20200316 114322459.jpg
Gripper can hit ring when carrying out the reverse move on V notch cutting Add
mrdummy.x=-300
to V notch mnd files


This will ensure a "minable" gap is always left at the gripper end to clear

ZX5 <250mm V Notch could cut into gripper or X axis beam The xholdpos will stop the V notch coming on if the x axis position is too low
4,-10000,820,OuB_VCut,True,X
8,-10000,1000,OuB_CLV,True,X


A an extra precaution, the mnd file can contain a wait to ensure the Beam is in its home position (out of the machine)
;Ensure the beam is out of the way
in.InC_BmPosH=1


End of Bar

Machine Limit Effect Solution
ZX5 Depth will be inaccurate because the backfence is not particularly good in this area Add
mrdummy.x=-300
to V notch mnd files


This will ensure a "maxable" gap is always left at the end of the bar and the V notch will be formed with a good backfence to reference and the V notch will be clamped securely from both sides