Tuning of EP7041 box is tricky, but following a step through telephone call with Etienne at Beckhoff, it was successful with the following steps
Auteur Gareth Green | Dernière modification 29/04/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Pas encore d'image
Tuning of EP7041 box is tricky, but following a step through telephone call with Etienne at Beckhoff, it was successful with the following steps
TB0371, Beckoff
Parameter | Notes | ZX5 SY | AF2 SY | AF2 GY | AF2 GZ |
8010 – 04 | Motor Coil Resistance (Small Motor 28 [0.28Ohm]) | 28 | 36 | 36 | 36 |
8010 – 06 | Motor FullSteps – always 200 for Beckhoff Steppers | 200 | 200 | 200 | 200 |
8010 – 07 | Encoder Increments – always 4096 for Beckhoff Steppers | 4096 | 4096 | 4096 | 4096 |
8012 - 05 | Speed range is max speed in motor steps, calculated from pitch, max speed etc.
Needs to tie up with Ref velocity in NC Parameters – see below |
2000 | 1000 | 1000 | 1000 |
8012 - 08 | Feedback type
Encoder feedback is best as it closes the loop. For open loop, use Internal, but this can loose steps / position |
Encoder | Encoder | Encoder | Encoder |
Following Any CoE change you need to do Online reset for EtherCAT master [Right click on Devicenn] NCAxis setup en none 0