Tuning of EP7041 box is tricky, but following a step through telephone call with Etienne at Beckhoff, it was successful with the following steps

Solution

Set up Remote box CoE Online Tab

TB0371 Setup of Beckoff Image.png


Parameter Notes ZX5 SY AF2 SY AF2 GY AF2 GZ
8010 – 04 Motor Coil Resistance (Small Motor 28 [0.28Ohm]) 28 36 36 36
8010 – 06 Motor FullSteps – always 200 for Beckhoff Steppers 200 200 200 200
8010 – 07 Encoder Increments – always 4096 for Beckhoff Steppers 4096 4096 4096 4096
8012 - 05 Speed range is max speed in motor steps, calculated from pitch, max speed etc.

Needs to tie up with Ref velocity in NC Parameters – see below

2000 1000 1000 1000
8012 - 08 Feedback type

Encoder feedback is best as it closes the loop. For open loop, use Internal, but this can loose steps / position

Encoder Encoder Encoder Encoder

Following Any CoE change you need to do Online reset for EtherCAT master [Right click on Devicenn] NCAxis setup