PC Configuration - ZX D

Auteur avatarGareth Green | Dernière modification 12/11/2019 par Gareth Green en cours de rédaction

Pas encore d'image

PC network configuration of the ZX3 / 4 following using a Beckhoff TwinCAT2 system on machining centre side and Nextmove ESB on Saw side

Summary

Setup follows the format of ZXC with two independent windows machines with independent control systems, but changing the MH control system from a Nextmove E100 card to Beckhoff TwinCAT2. In the ZX D format, there are 3 PCs in total

  1. Beckhoff CX5020 Windows Embedded PC running PLC code and front end
  2. Saw side PC on windows OS
  3. "Camera PC" used for dial in diagnostics and video, archive and data storage (CX5020 has limited hard drive capacity). The Camera PC shares \DDRIVE for MH side data and \SAW for saw side data.


All PCs have a network port and are connected through a 5 port switches located in the main cabinet, saw cabinet and a 3rd on the side of the MH machining module

PC Naming
MH Side Saw Side Camera PC
Z0nn

where nn is the build number

Z0nnS

where nn is the build number

Z0nnC

where nn is the build number

Folder Structure
MH Setup Files Saw Setup Files MH Front End Software Saw Front End Software
*.mul initialisation files
\\Z0nnC\DDRIVE\
mapped as d:\ from Z0nn
*.saw initialisation files
\\Z0nnC\SAW\
mapped as d:\ from Z0nnS

mapped as e:\ from Z0nn

written in vb.net
c:\multi\winmulti.exe
written in vb.net
d:\winStugaSawVB.exe

Location of folder structure of MH side and saw side can be changed in the local masterdir.saw. See https://stuga.dokit.app/wiki/Masterdir_File

Cameras

The b