Recovering the bar queue to match the number of bars on transfer table following a crash on winMulti
Auteur Gareth Green | Dernière modification 23/09/2019 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Recovering the bar queue to match the number of bars on transfer table following a crash on winMulti
winMulti, Crash, bar queue Recovery_of_Bar_Queue_following_winMulti_Crash_with_Offcuts.jpg
There have been cases of software crashing on the Stuga front end software, but the machine will continue to cut the holes and slots on the bar and eject it to the transfer table.
This creates the situation that the bar is physically finished, but the software has not registered it as finished.
This can lead to confusion for the operator and put the bar queue out of sync, which can lead to wasted profileFirst you need to check out the bar queue to see if it is the same as the actual bars on the transfer table
If there is one more bar actually on the table than on the bar queue screen, follow the process below to add the missing bar to the queue.
On the machining centre side, click anywhere on the top profile in the queue
This opens the bar edit screen on the "Offcuts" tab
When a bar has been properly registered as "Cut, the tick box will be ticked (as in (1))
The first one that is "Uncut" needs to be queued, so
Click Finish
This will create a bar on the saw side queue for the missing bar
Same number of bars on the table as on the screen