R0000712E Rotary Trunking

Auteur avatarGareth Green | Dernière modification 24/09/2024 par Gareth Green en cours de rédaction

Introduction

Tools Required


Standard set Hex keys

Standard socket set

Countersink bit and drill

Copper/hide hammer

Standard hss drill set


Parts Required


D0006210 pre assembled energy chain

D0003929 Access panel

D0003930 Circular guide

D0003985 Upper circular guard

D0007817 Circular guard

D0001171 plug bracket

P0001023 6mm y adapter x 9

P0000401 non return valve

Étape 1 - Adhesive

All bolts must have Loctite 243 adhesive applied unless otherwise stated.


All bolts must be marked with pen once completed to indicate adhesive and correct tension has been applied



Étape 2 - Prepare 1st guide Section

D0003985 needs preparing before fitting


1 All back plates for the rotary trunking need to be checked for correct countersink depth. Any protrusion from main face will case energy chain failure

Check and if proud, use a countersink to increase depth


Étape 3 - Fit Energy chain mounting bracket

Mounting bracket D0006240 needs fitting to D0003985


1 Measure position of bracket onto circular guard (291mm)

2 Use a pointed m5 grubscrew screwed into bracket hole indicated, hold in position on guard, and use hide hammer to transfer position mark

3 Drill to 6mm and fix bracket with m5x 16 cap head and large m5 washer

4 Drill 6mm through indicated hole

5 Fix with M5 x 16 countersink, large m5 washer and nyloc nut

6 This countersink bolt head must be flush to block. If proud, use a countersink bit to increase depth


Étape 4 - Prepare second section

Check countersink holes in D0003930 are to the correct depth . Rework with countersink if fasteners sit proud.



Étape 5 - Prepare 3rd section

Check countersink holes in D0007817 are to the correct depth . Rework with countersink if fasteners sit proud.



Étape 6 - Orientation

It is vital to achieve correct orientation of above parts


Use M8 holes indicated as reference point for fitting


Étape 7 - Fit D0007817

Mount D0007817 to main rotary base and fix with m5 x 10 countersink bolts



Étape 8 - Fit D0003930

Mount D0003930 to main rotary base and fix with m5 x 10 countersink bolts



Étape 9 - Fit D0003985

Mount D0003985 to main rotary base and fix with m5 x 10 countersink bolts



Étape 10 - Fit locking screw to energy chain

Drill and tap m3 to plugged end ONLY of energy chain assembly

Use m3 x 6 pan head bolt to secure


...Caution damage to cables is possible Use a shield over cables to protect



Étape 11 - Modify plug and mount echain bracket

1 Modify plug to allow cable and pipe clearance as shown

2 Modification is required to give access as indicated

3 Attach chain bracket plug on end of cables at this end, with 2 off m5 x 10 button head and washers


Étape 12 - Mount energy chain

1 Fix energy chain bracket as shown using 2 off m5 x 10 button heads and heavy washers

2 Add cable retention point. Fit small A0000248 tie base and secure with M4 x 6 button head


Étape 13 - Mount plug bracket

Fit assembled plug and bracket into position. Secure with 2 off M5 x 10 button sockets


Étape 14 - Finalise energy chain cables

1 Set ethercat cable and 6mm blue pipe to the length shown of 580mm


2 Fit tie wrap to cable restraint point once cable and pipe length are set

Étape 15 - Fit Access panel

1 slide access panel into position

2 Fix energy chain to panel with m5 x 16 button heads, washers and nyloc nuts