ACEpc Installing netedit with NetSetGo disk

Auteur avatarGareth Green | Dernière modification 25/06/2020 par Gareth Green en cours de rédaction

Introduction

This procedure will completely overwrite any data on the hard drive of the ACEpc.

This is not a problem on a flowline where the data resides on the main MH hard drive in a shared directory c:\saw.

If this process is to be carried out on a standalone saw or router, make sure the data is backed up first.


Étape 1 - Insert disk (Power off)

Power off the machine and insert the NetSetGo disk



Étape 2 - Power On

Switching on with the floppy disk in will boot from the floppy drive instead of the hard drive

Étape 3 - Format Hard Drive and copy Zip

The PC will boot from the floppy disk and you will be prompted
Proceed with format


Press Y


You will then be prompted

Volume label [enter]


Press Enter


This will format the hard drive and then copy all necessary network software as a ZIP file to the hard drive and then inflate it.

Étape 4 - Run NetEdit from command prompt

At DOS prompt, ensure you are on drive C: by typing

c:


And press enter


type

netedit


And press enter

Étape 5 - Set the saw name

Build number must be unique. If a flowline saw put an "s" on the end. i.e. F073S

Étape 6 - Saw IP address

This is supplied by customer. IT department


If testing in house it needs to be on the 192.168.16.xxx range.

e.g 192.168.16.101

Étape 7 - Multi Name

If this is for a Flowline - Build Number of Flowline machining center

Otherwise this will be the net NETBEUI name of the pc you are connecting to.

For testing at stuga this will be NAS1

Étape 8 - Multi IP

If this is for a Flowline - IP Address of Flowline machining center

Otherwise this will be the IP address of the pc you are connecting to.

For testing at stuga this will be 192.168.16.6

Étape 9 - Save + Exit

Press escape - then Y

The message:

Unable to open params.saw file

is normal.

Commentaires

Draft