R0000738 Pneumatic Installation

Auteur avatarGareth Green | Dernière modification 11/03/2024 par Gareth Green en cours de rédaction

Introduction

Tools Required


Pipe cutters

Pipe identification numbers


Parts Required


D0015703 Air Gun Bracket x 1

P0000010 Elbow Adaptor 6mm - 1/8 BSPT (Taper thread) x 2

P0000046 Fitting: 'Y' Adaptor 6mm x 4

P0000053 6mm T (P16) x 2

P0000075 Parallel Y Connector 8mm x 1

P0000077 Straight Adaptor 8mm - 1/8BSP x 3

P0000160 Fitting: Flow Controller In Line 6mm x 4

P0000161 Plug-in Reducer 6mm Tube 8mm Fitting x 6

P0000401 6mm inline non return valve x 2

P0000470 Valve: 5/2 PnPnu 1/8BSP x 1

P0000513 Ball valve with QS connector x 1

P0000551 6mm inline Quick Exhaust Fitting x 6

P0001106 Plug in reducer 12mm to 8mm x 7

P0001107 12mm Y connector x 8

R0015114 Bench Assemble Valve banks and Regulators


Étape 1 - Unless otherwise stated

Use Loctite 243 on all fasteners

Use Loctite 572 on all threaded pneumatic connection

Pen mark all fasteners to show finalised



Étape 2 - Y269 Ring blow output

Pipe id 2699


Pipe trailing from rotary head energy chain

Route into trunking and exit as shown to valve bank


Blank port 2

Étape 3 - Y270 Clamp hold

Pipe id 2701


Connect to port 2 on valve bank


Through trunking as shown


Connect to Nose of clamp hold cylinder


Pipe id 2709


Connect to port 4 on valve bank


Through trunking as shown


Leave 2 meter tails on both pipes exiting the trunking

Handing. Pipes always exit trunking as shown next to side clamp assembly

Étape 4 - Y350 Clamp infeed top

Pipe id 3501


Connect to port 2 on valvebank


Through trunking and exit at point shown


Pipe id 3509


Connect to port 4 of valvebank


Through trunking and exit at point shown


Pipe ID 3502

Run pipe between points shown







Étape 5 - Y351 infeed side clamp

Pipe ID 3511


Connect to port 2 on valve bank


Through trunking and exit at point shown


Pipe ID 3519


Connect to port 4 on valvebank


Through trunking and exit as shown


Pipe ID 3512


Through trunking and exit as shown


leave pipes coiled up ready for later connection

Étape 6 - Y360 work blowers

Pipe Id 3609


Connect to port 4 on valvebank


Blank port 2


Route through trunking and exit as shown.

Leave 1.5meters of pipe from trunking exit

Handing, pipe will always exit trunking at side shown opposite to side clamp connections


Étape 7 - Y386 Outfeed clamps

Pipe 3861

From port 2 of valvebank directly up to clamp area shown

3862 routes from clamp area to point shown out of trunking

3863 routes from clamp area to point shown out of trunking

3869 connects from port 4 on valve bank and routes to trunking exit point as shown


Étape 8 - Y389 V cut

Connect pipe 3891 to port 2 of valve bank and route as shown . Leave 1 meter tail exiting trunking


Connect pipe 3899 to port 4 of valve bank and route as shown . Leave 1 meter tail exiting trunking


Handing. Pipe exit will always be the trunking closet to the support cylinder with air adjustment fittings

Étape 9 - Y389 V cut

Amendment . Top clamp cylinder now using 2 off standard P0000010 elbows and 2 off P0000160inline flow regulators for easier access

Pipe ID 3891

Connect port 2 of valve bank to port 12 of 5/2 valve

Connect port 2 of 5/3 valve to base of VZ cut cylinder with 8mm black air pipe


Pipe ID 3899


Connect port 4 of valve bank to port 10 on 5/3 valve

Connect 4 on 5/3 valve to nose of VZ cut cylinder with 8mm black airpipe

Cut 8mm Y connector into pipe alongside cylinder and and fit 8 to 6mm reducer


Connect 6mm black airpipe from y connector to pilot check valve at base of cylinder


Étape 10 - Y395 Clamps V

Pipe ID 3951


Connect port 2 on valve bank


Through trunking


Add 6mm Y connector to create 2 3951 feed pipes


Connect to noses of top and side v notch clamps


Pipe ID 3959


Connect to port 4 of valve bank


Through trunking


6mm tee connector


Feed both IN ports on Y395 top clamp and Y395 side clamp regulators


Pipe ID 3952


Connect OUT port on Y395 top clamp regulator


Through trunking


Connect to inline flow regulator

Connect to base of v clamp top cylinder . P0000551 QEV must be fitted

Pipe ID 3953

Connect to OUT port on Y395 V clamp side regulator

Connect to inline flow regulator near cylinder

Connect inline flow regulator to base of side clamp cylinder . P0000551 must be fitted next to cylinder


Étape 11 - 12mm blue connections Ring feed

Connection for 12mm ring main as follows


Front lower 12mm bulkhead to connect to 12mm Y connector at point A indicated


Add 12mm to 8mm reducer then 8mm to 6mm reducer into Y fitting and connect 6mm blue airpipe to feed up to point B


Étape 12 - 12mm blue connections Valve bank supply

Connect previous fitted Y connector to a new 12mm Y connector at point A


Add 12mm blue pipe to feed valve bank , exit pipe through slot to feed valve bank



Étape 13 - 12mm blue connection V cut valve

Connect previous 12mm Y connector to new 12mm Y connector at point A


Use 12mm to 8mm reducer and connect 8mm blue air pipe , feed out of grommit and supply 5/3 v notch valve



Étape 14 - 12mm blue connection

Connect previous fitted 12mm Y connector to rear lower panel 12mm bulkhead .


Run pipe along rear basket



Étape 15 - Ring supply Anti drop system

Connect 6mm blue feed pipe to non return valve at indicated point


Connect 6mm Y connector to non return valve


Connect feed pipe from ring assembly to one port of Y connector


Connect 6mm pipe to second port of Y connector and run pipe to point B


Add P0000513 q ball valve


Connect 6mm blue pipe to Q valve to run into energy chain and act as exhaust



Étape 16 - 12mm red Connection Bulkhead /Air gun

Connect 1st 12mm bulkhead on lower front panel with 12mm red pipe


Add 12mm Y connector at point A and fit 12mm to 8mm reducer then add 8mm red pipe to exit trunking and feed Air gun regulator port IN



Étape 17 - 12mm Red connection Z support cylinder

Add new 12mm Y Connector at point A and connect to previous Y connector .


Add 12mm to 8mm reducer and 8mm to 6mm reducer to provide 6mm red pipe to feed to Z support cylinder regulator port IN


Add P0000501 non return to 6mm red pipe just before entry into In port



Étape 18 - 12mm red connection VZ support cylinder

Add 12mm Y connector at point indicated and connect to previous 12mm Y connector


Add 12mm to 8mm reducer and connect 8mm red pipe to feed VZ regulator port IN



Étape 19 - 12mm red connection Z support pilot 1

Add 12mm Y connector at point A


Add 12mm to 8mm reducer, then 8mm to 6mm reducer , then connect 6mm red pipe to exit through grommit and feed pilot valve on z support cylinder 1



Étape 20 - 12mm red connection rear lower panel

Connect previous fitted 12mm Y connector to rear 12mm bulkhead fitting


run pipe along wire basket at rear



Étape 21 - 12mm red connection 12mm from bulkhead

Connect 12mm red pipe front front 12mm bulkhead to Y connector at indicated point


fit 12mm to 8mm reducer then 8mm to 6mm reducer and connect 6mm red pipe to feed pilot valve on z support cylinder 2



Étape 22 - 12mm red connection rear bulkhead

Connect previous fitted Y connector to rear bulkhead with 12mm pipe



Étape 23 - Z support cylinder Feeds

Connect 6mm red pipe to Out port on Z support cylinder


Add 6mm Y connector and connect 2 off 6mm red airpipes to route into trunking and feed both Z support check valves



Étape 24 - VZ support cylinder feed

Connect 8mm red pipe to OUT port on VZ support regulator and feed base QEV valve on VZ support cylinder



Étape 25 - Z support exhaust

Add 6mm black airpipes to QEV on z support cylinders


Run through trunking to exit point indicated


Connect to blowers on swarf chute



Commentaires

Draft