Installation steps for Electrical looms installation into Module B
Auteur Gareth Green | Dernière modification 27/02/2024 par Stuga Engineer en cours de rédaction ⧼frevu-button-review-label⧽
Installation steps for Electrical looms installation into Module B
R0015034B_ZX5_Module_B_Wiring_Loom_installation_Screenshot_2024-02-21_085621.png
Parts Required
Pre labelled Wiring loom assembly R0015034B from electrical team
Tools required
Flush cutters
Tie wraps small
Tie Wraps Large
All bolts to have Loctite 243 adhesive applied unless otherwise stated
All Threaded Pneumatic connections to have Loctite 570 applied
All bolts to be pen marked once adhesive applied and correct tension added
{Pictures show L-R configuration. For R-L use additional tie base shown
1 Use cables X56 and X488 from loom box.
2 Connect as shown to sensor and flying lead X488
3 Cut and label 1 off 6mm black air pipe 2699 @ 5 mtrs
4 Loom as shown utilising tie bases as indicated
Use cable marked as R axis from loom box
1 Connect to servo motor, and fit protective cover to finalise .Ensure panel edging strip is fitted to indicated faces shown
2 Captivate cable onto gearbox as shown with large tie wraps
3 Fix to rear faceplate using M4 tie base. Ensure cable sits free of main shaft
4 Fix cable as shown using large tie bases
Loom cables and pipe from rotary head, fix with 2 off small tie bases
Run cables from step 2-4 through energy chain, ensuring no twists are present .
Ensure cable retention points are used at both ends of energy chain .
Use P0000046 Y connector and P0000159 6mm blank to direct 2699 pipe as shown ( this is required to ensure pipe does not kink when entering energy chain)
Ensure that rotary head is moved fully in both directions side to side to ensure that loom lengths entering the energy chain are correct and no tension is applied to cable looms
1 Route R axis cable as shown through trunking
2 Pass large servo plug through vertical trunking dogleg .
3 Exit cable from frame at rear as shown
1 Retrieve cable identified as Z axis from loom box
2 Pass small plug through trunking grommit shown and connect to servo motor
3 Route and exit rear as shown
1 Retrieve X50 from wiring loom box , and Fit to Y axis datum point
2 Attach cable tie bases small and route cable as shown
1 Identify Y axis cable from loom box
2 Connect and loom as shown , incorporating previous fitted X50 cable
3 Run through energy chain as shown, ensure cable retention points are used
en none 0 Draft
Vous avez entré un nom de page invalide, avec un ou plusieurs caractères suivants :
< > @ ~ : * € £ ` + = / \ | [ ] { } ; ? #