R0015119 Mount Assemblies

Auteur avatarGareth Green | Dernière modification 18/01/2024 par Gareth Green en cours de rédaction

Introduction

Tools Required


Standard hex key set

Standard spanner set

Standard hss drill set

Standard tap set


Parts Required


D0004600 Outfeed Eject Bar

R0015342 Bench Assemble Outfeed Parts


Étape 1 - Unless otherwise stated

Use Loctite 243 on all fasteners

Use Loctite 570 on all threaded pneumatic connections

Pen mark all bolts when finalised



Étape 2 - Check correct position for mounting

Note that main fixing bar is unhanded and will have various mounting points for components.

Double check correct holes are used for fixing assemblies. Follow steps below to identify correct mounting points



Étape 3 - Mount cylinder assemblies

Attach 2 off pre built cylinder assemblies from R0015342 as shown using 4 off M6 x 20 socket caps and M6 heavy washers . Do not apply tension to these bolts as they will need adjusting


Étape 4 - Attach push eject bar

1 Attach D0004600 Outfeed Eject Bar x1 as shown using 4 off M6 x 25 socket caps. Apply only light pressure to these fixings


2 Ensure cylinder assemblies are retracted to the position shown


3 Finalise fixings ( 4 off 2 per cylinder assembly) shown to set correct pitching between cylinder assemblies


4 Set correct push bar position. Slacken indicated fixings and set push bar at its highest point as indicated


5 Finalise 4 off fixings that hold the push bar

Étape 5 - Finalise position of cylinder stroke

1 Measure 1 cylinder assembly at position shown


2 Adjust cylinder stroke of second assembly to replicate this first measurement


3 Double check all fixings have been Finalised including cylinder stroke lock nuts



Étape 6 - Mount valve bank

Mount Pre assembled valve bank from R0015342 at the position shown. Use 2 off M4 x 40 socket caps and A form washers to fix.


If pre drilled holes are not present, drill 2 off M4 tapped holes to position the valve bank to the measurements shown


Étape 7 - Mount safety gate assembly

Do not apply adhesive or finalise fixings


Use 3 off M8 x 20 socket caps with M8 heavy washers to fix safety gate into position shown

To Fix cylinder base to frame, use the following fasteners

1 off M6 x 50 socket cap 2 off M6 A Form washer 1 off M6 standard nut 1 off M6 Nyloc nut

See Photo for orientation