Details to install pneumatic and electrical loom
Auteur Gareth Green | Dernière modification 27/02/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Details to install pneumatic and electrical loom
R0015146_Pneumatic_pipe_Installation_Part_3_Screenshot_2023-12-14_145058.png
This instruction is to incorporate assembly R0015033B Module F Wiring loom alongside this
See Electrical department for prepared components from above assembly
Tools Required
Pipe cutters
Pipe identification markers
Flush cutters
Parts Required
P0000010 6mm 1/8 elbow fitting x 6 P0000046 Fitting: 'Y' Adaptor 6mm x 6
P0000047 Bulkhead Elbow 6mm x 1
P0000159 Fitting: Stem Blanking Plug 6mm x 2
P0000160 Fitting: Flow Controller In Line 6mm x 2
P0000551 6mm inline Quick Exhaust Fitting x 3
P0001030 Fitting: SMC 6mm Equal Tee x 1
P0001008 regulator x 3
P0001009 Regulator nut x 3
P0001106 Plug in reducer 12-8mm x 1
P0001107 Fitting 12mm equal tee x 1
P0001166 12mm tube to tube elbow x 1All bolts to have Loctite 243 adhesive applied unless otherwise stated
All Threaded Pneumatic connections to have Loctite 570 applied
All bolts to be pen marked once adhesive applied and correct tension added
1 Cut 1 off 6mm black pipe at 5 meter and add identification of 2149
2 Use cable 13F1 and 13F from cable loom box
3 Attach pipe and cable as shown
4 Loom additional cable 13F as shown
1 Cut 1 off 6mm black pipe at 5.5 meters and identify as 2159
2