4 x G clamps are Required It is for 2 x People - 3 days
Gareth Green
Jan 30 at 10:44 am

1 Réponse(s)
Z055 - ZX4 has been fitted using existing Software setup so Ou_InvDP not used (24v linked to S3 and S4.X308 - Inverter Zero fitted but not used. Uses Drive Run Fwd not using SMOT.
Gareth Green
May 2 at 7:01 pm

0 Réponse(s)
STO alarm Please see https://stuga.dokit.app/wiki/Yaskawa_Inverter_-_Fault_and_Alarm_Output_Functionality Once wiring changes have been made, change parameter H2-03 to 110. This can be done online via DriveWizard or directly through the inverter touchpad.
Gareth Green
Mar 13 at 5:30 pm

0 Réponse(s)
Gareth Green
Nov 21 at 5:01 pm

0 Réponse(s)
Newer Versions have battery in a different place (Z073) - Photos added to Step 2 and also its Soldered in with a connector These are on the H370M- ITX Gen3 x4 Motherboards
Gareth Green
Aug 14 at 3:28 pm

0 Réponse(s)
Datum Spindle is a Spindle with a 10mm Tool fitted .
Gareth Green
Jul 9 at 11:00 am

0 Réponse(s)
Also Done to F031 - Who use ZEB FDS label Width set to 832 Left margin offset -30 (3mm)
Gareth Green
Jan 30 at 5:19 pm

0 Réponse(s)
On the original FDS Zeb files the label format is for 102mm Width to get the new printers to work you need set width at 832 (102mm) and in Advanced settings set left Position at -30 (-3mm) which will allow the label to work on a 99mm width
Gareth Green
Jun 19 at 12:11 pm