Testing procedure for installed pneumatics
Auteur Gareth Green | Dernière modification 4/12/2023 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Testing procedure for installed pneumatics
R0015114_Bench_Assemble_Valve_Banks_and_Regulators_Screenshot_2023-11-02_074048.png
Tools Required
Standard screwdriver set
Parts Required
Output testing will be carried out under a no-emergency stop situation
ensure pcl coupling is used for ability for quick disconnection
Ensure all colleagues are aware of testing and ensure good working practise is followed
Ensure soft start adjuster is fully wound out
Set air service unit to 6 bar
Check for audible leaks and correct if required
Check operation of air gun . Ensure pressure is set to maximum of 2 bar
Set Z axis support pressure. Set at 5 bar, and adjust to balance. Rotary ring should be held in position under cylinder pressure, but be able able to be moved up and down by turning the leadscrew by hand
If resistance is felt or axis bounces when leadscrew is turned , check air connections for correct piping
Manually override air service unit to purge Blue ring main
Caution All cylinders should move to their home positions
Check for audible leaks from ring main and cylinder connections
Check for leaks when all outputs are individually fire also
Home position Blower should be switched off
Fire valve, blower should activate on tool break sensor assembly
Check orientation of in line flow regulator . Fully closed, air feed should stop totally . If not possible, flow regulator is fitted incorrectly
Home position is retracted away from bottom rollers
Manually fire valve, cylinder should move toward datum rollers
Home position should be lifted up
Manually fire valve, set regulator pressure to 2 bar
Clamp should move down when fired
Home position should be retracted away from datum rollers
Manually fire valve, set regulator pressure to 2 bar
Clamp should move in when fired
Home position Blower should be switched off
Fire valve, blower should activate on infeed datum roller assembly
Check orientation of in line flow regulator . Fully closed, air feed should stop totally . If not possible, flow regulator is fitted incorrectly
Shared Output for top and side clamp
Home positions are
side clamp retracted away from datum rollers
Top clamp retracted away from datum rollers
Manually fire valve
Set
Y386 side clamp regulator to 2 bar
Y386 top clamp regulator to 2 bar
Clamps should move towards datum rollers
Ensure all clamps are clear from V notch cut axis
Home position should be up
Manually fire valve
V notch assembly should move down towards the floor
Y395 is a shared output for V top and side clamp
Home positions are
side clamp retracted away from datum rollers
Top clamp retracted away from datum rollers
Manually fire valve
Set
Y395 side clamp regulator to 4 bar
Y395 top clamp regulator to 4 bar
Clamps should move towards datum rollers when fired