Correct installation , setting and quality checks for installation of material sensor beam
Auteur Gareth Green | Dernière modification 29/01/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Correct installation , setting and quality checks for installation of material sensor beam
R0015293_Install_Flap_Sensor_Beam_Screenshot_2023-10-30_145001.png
Tools Required
Standard hex key set
2 Meter straight edge
Parts Required
R0015060 Bench Assemble Flapper Beam
Use Loctite 243 on all fasteners
Use Loctite 572 on all threaded pneumatic connection
Pen mark all fasteners to show finalised
(front transfer beam removed for clarity )
Fix assembled beam to supports as shown
Do not finalise fasteners
Use sliding adjustment on maytec angles /frame to adjust height of assembly
To determine correct height Set end A and B separately
Span over transfer beams 1 and 2 with straight edge at point A
Lift or lower sensor rail assembly to match the following criteria
When straight edge is pushed to meet radius of sensor plate, it must strike at indicated point of halfway around radius on paddle
Repeat height setting at point B using same criteria
Once point B is set, check that point A has not altered
Once correct settings have been achieved, double check and finalise all fasteners used for adjusting and mounting .
Ensure all fasteners have 243 applied to threads and are pen marked as complete