Details for manual pneumatic output testing on module
Auteur Gareth Green | Dernière modification 2/04/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Details for manual pneumatic output testing on module
R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_135339.png
Tools Required
PCL airline connection
12mm blanking ports
Valve Manual over ride tool
Standard screwdriver set
Additional colleague when setting regulator pressures for outputs
Parts required
Output testing will require valve operation with no e/s circuit
Ensure the following
Work area is clear from all components not required for testing
All colleagues are aware of the procedure being undertaken
No additional colleagues are working on the module
PCL coupling is accessible to release pressure in case of emergency
Testing procedure is fully adhered to
Wind fully out soft start screw situated on top on main air service unit
Connect main pcl air feed to air service unit
Increase Air service unit pressure to 6.0bar /6mpa
Check for audible leaks on the red pipe lines installed and correct if found
Check air gun regulator functions properly . Fully open the regulator (2 bar limited ) and test air gun assembly
Enable the manual over ride on the main air service unit
This will purge the system with air.
Check for audible leaks on blue Pipe line, and active control pipes to cylinders and regulators
With the system in the natural state when over ridden, the following cylinder positions should be confirmed
Y80 Infeed Top clamp contracted
Y82 Outfeed top clamp contracted
Y91 eject cylinder contracted
Y202 clamp infeed side extended
Y204 Clamp pos contracted
Y206 Centralise contracted
Y207 Saw cut contracted
Y210 Z support infeed contracted
Y213 Saw blowers switched off
Y214 Z turret infeed Not moving
Y215 Z turret outfeed . Not moving
Y224 Z support outfeed contracted
If any deviation from the above check pipe connections to incorrect output
Each valve can be manually fired from the over ride button. Pressing this will activate the valve and fire the cylinder /output
when a valve is over ridden, ensure attention is paid to any new air leaks that could become present in the active line when fired
Fire and hold valve
Adjust regulator to 2 M.P.A
Cylinder should extend
Should retract when valve released
Fire and hold valve
Cylinder should extend
Should retract when valve released
Fire and hold valve
Eject table should move away from saw head
Should retract when valve released
Fire and hold valve
Set regulator to 2 M.P.A
Side clamp should move towards backfence rollers
Should retract when valve released
Fire and hold valve
Clamps should move towards from of machine.
If movement is slow/not present check flow restrictors on back of electrical cabinet identified as 2049
Should retract when valve released
Fire and hold valve
Set regulator to 2 M.P.A
Saw head should move towards rear of machine
Should retract when valve released
Fire and hold valve
Saw head should raise up
Should retract when valve released
Fire and hold valve
Infeed side z block should fire towards back fence
Should retract when valve released
assistance required from colleague
Fire and hold Y80 output , infeed top clamp should move down. Keep Y80 held down
Top clamp block pressure should be weak enough to override by hand and move clamp back towards cylinder
Additionally fire Y212, this should switch clamp to high pressure and stop clamp being able to be over ridden by hand
Fire and hold valve
Blowers should switch on
Check operation of inline flow controllers .
When fully closed air flow should stop completely. If air flow can not be completely stopped by flow controller, it is fitted the wrong way around. Change and recheck if this occurs
Fire and hold valve
Infeed turret should rotate once
Release and fire valve again and turret should again rotate one position
Fire and hold valve
Outfeed turret should rotate once
Release and fire valve again and turret should again rotate one position
Fire and hold valve
Outfeed side z block should fire towards back fence
Should retract when valve released