Installation of rotary energy chain and back plates
Auteur Gareth Green | Dernière modification 24/09/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Installation of rotary energy chain and back plates
R0000712E_Rotary_Trunking_Screenshot_2023-05-31_080328.png
Tools Required
Standard set Hex keys
Standard socket set
Countersink bit and drill
Copper/hide hammer
Standard hss drill set
Parts Required
D0006210 pre assembled energy chain
D0003929 Access panel
D0003930 Circular guide
D0003985 Upper circular guard
D0007817 Circular guard
D0001171 plug bracket
P0001023 6mm y adapter x 9
P0000401 non return valveAll bolts must have Loctite 243 adhesive applied unless otherwise stated.
All bolts must be marked with pen once completed to indicate adhesive and correct tension has been applied
D0003985 needs preparing before fitting
1 All back plates for the rotary trunking need to be checked for correct countersink depth. Any protrusion from main face will case energy chain failure
Check and if proud, use a countersink to increase depth
Mounting bracket D0006240 needs fitting to D0003985
1 Measure position of bracket onto circular guard (291mm)
2 Use a pointed m5 grubscrew screwed into bracket hole indicated, hold in position on guard, and use hide hammer to transfer position mark
3 Drill to 6mm and fix bracket with m5x 16 cap head and large m5 washer
4 Drill 6mm through indicated hole
5 Fix with M5 x 16 countersink, large m5 washer and nyloc nut
6 This countersink bolt head must be flush to block. If proud, use a countersink bit to increase depth
Check countersink holes in D0003930 are to the correct depth . Rework with countersink if fasteners sit proud.
Check countersink holes in D0007817 are to the correct depth . Rework with countersink if fasteners sit proud.
It is vital to achieve correct orientation of above parts
Use M8 holes indicated as reference point for fitting
Drill and tap m3 to plugged end ONLY of energy chain assembly
Use m3 x 6 pan head bolt to secure
1 Modify plug to allow cable and pipe clearance as shown
2 Modification is required to give access as indicated
3 Attach chain bracket plug on end of cables at this end, with 2 off m5 x 10 button head and washers
1 Fix energy chain bracket as shown using 2 off m5 x 10 button heads and heavy washers
2 Add cable retention point. Fit small A0000248 tie base and secure with M4 x 6 button head
Fit assembled plug and bracket into position. Secure with 2 off M5 x 10 button sockets
1 Set ethercat cable and 6mm blue pipe to the length shown of 580mm
2 Fit tie wrap to cable restraint point once cable and pipe length are set
1 slide access panel into position
2 Fix energy chain to panel with m5 x 16 button heads, washers and nyloc nuts