quality checks and frame levelling
Auteur Gareth Green | Dernière modification 3/04/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
quality checks and frame levelling
R0015327_Level_Frame_and_quality_Check_Screenshot_2023-10-20_093359.png
Tools Required
2 meter straight edge
1 meter steel rule
300mm engineers level
Standard spanner set
Copper grease
Standard tap set
Tape Measure
Standard ratchet/socket set
Parts Required
Workshop consumable floor pads
D0004576e frame x 1
M12 x 100 set bolts x 4
M12 Standard nut x 4Fit 4 off M12 set bolts with M12 nut and copper slip to frame for levelling
Position black levelling pads beneath each bolt
check indicated projection using 2 meter straight edge
check all 4 points
150mm -+ 2mm
Use 1 meter steel rule or tape measure to check parallel of faces indicated
Report any deviation to supervisor
Use M12 bolts to level frame on the Y axis . Use indicated area to set level of frame
Ensure levelling face is flat
Level X axis using indicated faces
Ensure Y axis level is maintained when adjusting X axis
Take an average over the 4 indicated points to set x axis level