[version en cours de rédaction] | [version en cours de rédaction] |
Ligne 39 : | Ligne 39 : | ||
<code>c:</code> | <code>c:</code> | ||
+ | |||
And press enter | And press enter | ||
Ligne 46 : | Ligne 47 : | ||
<code>netedit</code> | <code>netedit</code> | ||
+ | |||
And press enter</translate> | And press enter</translate> | ||
Ligne 51 : | Ligne 53 : | ||
{{Tuto Step | {{Tuto Step | ||
|Step_Title=<translate>Set the saw name</translate> | |Step_Title=<translate>Set the saw name</translate> | ||
− | |Step_Content=<translate></translate> | + | |Step_Content=<translate>Build number must be unique. If a flowline saw put an "s" on the end. i.e. F073S</translate> |
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Saw IP address</translate> | ||
+ | |Step_Content=<translate>This is supplied by customer. IT department | ||
+ | |||
+ | |||
+ | <small>''If testing in house it needs to be on the 192.168.16.xxx range.''</small> | ||
+ | |||
+ | <small>''e.g 192.168.16.101''</small></translate> | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Multi Name</translate> | ||
+ | |Step_Content=<translate>If this is for a Flowline - Build Number of Flowline machining center | ||
+ | |||
+ | Otherwise this will be the net NETBEUI name of the pc you are connecting to. | ||
+ | |||
+ | <small>''For testing at stuga this will be NAS1''</small></translate> | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Multi IP</translate> | ||
+ | |Step_Content=<translate>If this is for a Flowline - IP Address of Flowline machining center | ||
+ | |||
+ | Otherwise this will be the IP address of the pc you are connecting to. | ||
+ | |||
+ | <small>''For testing at stuga this will be 192.168.16.6''</small></translate> | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Save + Exit</translate> | ||
+ | |Step_Content=<translate>Press escape - then Y | ||
+ | |||
+ | The message: | ||
+ | |||
+ | <code>Unable to open params.saw file</code> | ||
+ | |||
+ | is normal.</translate> | ||
}} | }} | ||
{{Notes}} | {{Notes}} |
Using a NetSetGo disk to reformat an ACEpc hard drive and install all the correct software to enable IP address networking
Auteur Gareth Green | Dernière modification 25/06/2020 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Using a NetSetGo disk to reformat an ACEpc hard drive and install all the correct software to enable IP address networking
ACEpc, netsetgo, networking ACE_PC_Re-Flash_20190827_142747.jpg
This procedure will completely overwrite any data on the hard drive of the ACEpc.
This is not a problem on a flowline where the data resides on the main MH hard drive in a shared directory c:\saw.
If this process is to be carried out on a standalone saw or router, make sure the data is backed up first.
Volume label [enter]
This will format the hard drive and then copy all necessary network software as a ZIP file to the hard drive and then inflate it.
At DOS prompt, ensure you are on drive C: by typing
c:
And press enter
type
netedit
And press enter
Build number must be unique. If a flowline saw put an "s" on the end. i.e. F073S
This is supplied by customer. IT department
If testing in house it needs to be on the 192.168.16.xxx range.
e.g 192.168.16.101
If this is for a Flowline - Build Number of Flowline machining center
Otherwise this will be the net NETBEUI name of the pc you are connecting to.
For testing at stuga this will be NAS1
If this is for a Flowline - IP Address of Flowline machining center
Otherwise this will be the IP address of the pc you are connecting to.
For testing at stuga this will be 192.168.16.6
Press escape - then Y
The message:
Unable to open params.saw file
is normal.