90mm Z Profile Modifications : Différence entre versions

[version en cours de rédaction][version en cours de rédaction]
(Page créée avec « {{Tuto Details |Main_Picture=90mm_Z_Profile_Modifications_Screenshot_2023-11-10_144600.jpg |Main_Picture_annotation={"version":"2.4.6","objects":[{"type":"image","version"... »)
 
Ligne 10 : Ligne 10 :
  
  
A larger Z block is also added D0015178B to prevent potential pivot points on the taller Z section.
+
A larger Z block is also added D0015178B to prevent potential pivot points on the taller Z section.{{#annotatedImageLight:Fichier:90mm Z Profile Modifications Image 3.png|0=346px|hash=|jsondata=|mediaClass=Image|type=frameless|align=center|src=https://stuga.dokit.app/images/8/88/90mm_Z_Profile_Modifications_Image_3.png|href=./Fichier:90mm Z Profile Modifications Image 3.png|resource=./Fichier:90mm Z Profile Modifications Image 3.png|caption=|size=346px}}
  
 
=Spindle Plunge Bracket Interference=
 
=Spindle Plunge Bracket Interference=
Ligne 18 : Ligne 18 :
 
'''Solution''':
 
'''Solution''':
  
# Increase the plunge length of a specific tool
+
#Increase the plunge length of a specific tool
# Create a special drainage operation for DFR on LCW9022
+
#Create a special drainage operation for DFR on LCW9022
# Create a variable for the flowops editor to allow a tool depth offset on screen when this tool is selected
+
#Create a variable for the flowops editor to allow a tool depth offset on screen when this tool is selected
 
{{Info|...A special tool number of 9 is used in this instance so it does not affect the programming depth of all other 5mm drainage tools}}<br /></translate>
 
{{Info|...A special tool number of 9 is used in this instance so it does not affect the programming depth of all other 5mm drainage tools}}<br /></translate>
 
{{PageLang
 
{{PageLang
 +
|Language=en
 
|SourceLanguage=none
 
|SourceLanguage=none
 
|IsTranslation=0
 
|IsTranslation=0
|Language=en
 
 
}}
 
}}
 
{{AddComments}}
 
{{AddComments}}

Version du 10 novembre 2023 à 16:15

Auteur avatarGareth Green | Dernière modification 10/11/2023 par Gareth Green en cours de rédaction

Modification necessary to allow 90mm tall profile Z sections to be handles by Stuga Machines Liniar LCW9022

Sawing Clamps - ZX5

The side clamp block D0015174 are modified to allow a roller at a higher position to coincide with the top edge of the 90mm profile

90mm Z Profile Modifications Screenshot 2023-11-10 145428.jpg

This is a permanent change to this block, and the additional rollers can be fitted as an optional extra - kit is R00xxxxxx


A larger Z block is also added D0015178B to prevent potential pivot points on the taller Z section.

90mm Z Profile Modifications Image 3.png

Spindle Plunge Bracket Interference

During testing the DFR operation could not complete the plunge because the spindle plunge bracket interferes with the bottom edge of the profile

90mm Z Profile Modifications Image 2.png
90mm Z Profile Modifications Image 1.png


There is no way around this issue with the tool depth set at the standard positions (level with inside of the ring)

90mm Z Profile Modifications Screenshot 2023-11-10 144600.jpg


Solution:

  1. Increase the plunge length of a specific tool
  2. Create a special drainage operation for DFR on LCW9022
  3. Create a variable for the flowops editor to allow a tool depth offset on screen when this tool is selected
...A special tool number of 9 is used in this instance so it does not affect the programming depth of all other 5mm drainage tools


Commentaires

Draft