Standard screwdriver set | Standard screwdriver set | ||
+ | |||
+ | Additional colleague when setting regulator pressures for outputs | ||
Ligne 76 : | Ligne 78 : | ||
Check air gun regulator functions properly . Fully open the regulator (2 bar limited ) and test air gun assembly</translate> | Check air gun regulator functions properly . Fully open the regulator (2 bar limited ) and test air gun assembly</translate> | ||
|Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140328.png | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140328.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Manual overide</translate> | ||
+ | |Step_Content=<translate>Enable the manual over ride on the main air service unit | ||
+ | |||
+ | |||
+ | This will purge the system with air.</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_135953.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Check for leaks</translate> | ||
+ | |Step_Content=<translate>Check for audible leaks on blue Pipe line, and active control pipes to cylinders and regulators</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Check home positions</translate> | ||
+ | |Step_Content=<translate>With the system in the natural state when over ridden, the following cylinder positions should be confirmed</translate> | ||
+ | |Step_Picture_00=R0015338_Bench_Assemble_Serial_Plate_caution.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>home positions for outputs</translate> | ||
+ | |Step_Content=<translate>Y80 Infeed Top clamp contracted | ||
+ | |||
+ | Y82 Outfeed top clamp contracted | ||
+ | |||
+ | Y91 eject cylinder contracted | ||
+ | |||
+ | Y202 clamp infeed side extended | ||
+ | |||
+ | Y204 Clamp pos contracted | ||
+ | |||
+ | Y206 Centralise contracted</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>home positions for outputs</translate> | ||
+ | |Step_Content=<translate>Y207 Saw cut contracted | ||
+ | |||
+ | Y210 Z support infeed contracted | ||
+ | |||
+ | Y213 Saw blowers switched off | ||
+ | |||
+ | Y214 Z turret infeed Not moving | ||
+ | |||
+ | Y215 Z turret outfeed . Not moving | ||
+ | |||
+ | Y224 Z support outfeed contracted | ||
+ | |||
+ | <br /></translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>If any deviation from the above</translate> | ||
+ | |Step_Content=<translate>If any deviation from the above check pipe connections to incorrect output</translate> | ||
+ | |Step_Picture_00=R0015338_Bench_Assemble_Serial_Plate_caution.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Manual valve over ride</translate> | ||
+ | |Step_Content=<translate>Each valve can be manually fired from the over ride button. Pressing this will activate the valve and fire the cylinder /output | ||
+ | |||
+ | |||
+ | when a valve is over ridden, ensure attention is paid to any new air leaks that could become present in the active line when fired</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Y80 Clamp infeed top</translate> | ||
+ | |Step_Content=<translate>Fire and hold valve | ||
+ | |||
+ | |||
+ | Adjust regulator to 2 M.P.A | ||
+ | |||
+ | |||
+ | Cylinder should extend | ||
+ | |||
+ | |||
+ | Should retract when valve released</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Y82 Clamp outfeed top</translate> | ||
+ | |Step_Content=<translate>Fire and hold valve | ||
+ | |||
+ | |||
+ | Cylinder should extend | ||
+ | |||
+ | |||
+ | Should retract when valve released</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Y91 Eject</translate> | ||
+ | |Step_Content=<translate>Fire and hold valve | ||
+ | |||
+ | |||
+ | Eject table should move away from saw head | ||
+ | |||
+ | |||
+ | Should retract when valve released</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Y202 Side clamp</translate> | ||
+ | |Step_Content=<translate>Fire and hold valve | ||
+ | |||
+ | |||
+ | Set regulator to 2 M.P.A | ||
+ | |||
+ | |||
+ | Side clamp should move towards backfence rollers | ||
+ | |||
+ | |||
+ | Should retract when valve released</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Y204 Clamp position</translate> | ||
+ | |Step_Content=<translate>Fire and hold valve | ||
+ | |||
+ | |||
+ | Clamps should move towards from of machine. | ||
+ | |||
+ | |||
+ | If movement is slow/not present check flow restrictors on back of electrical cabinet identified as 2049 | ||
+ | |||
+ | |||
+ | Should retract when valve released</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Y206 Centralise</translate> | ||
+ | |Step_Content=<translate>Fire and hold valve | ||
+ | |||
+ | |||
+ | Set regulator to 2 M.P.A | ||
+ | |||
+ | |||
+ | Saw head should move towards rear of machine | ||
+ | |||
+ | |||
+ | Should retract when valve released | ||
+ | |||
+ | <br /></translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Y207 saw cut</translate> | ||
+ | |Step_Content=<translate>Fire and hold valve | ||
+ | |||
+ | |||
+ | Saw head should raise up | ||
+ | |||
+ | |||
+ | Should retract when valve released</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Y210 Z support infeed</translate> | ||
+ | |Step_Content=<translate>Fire and hold valve | ||
+ | |||
+ | |||
+ | Infeed side z block should fire towards back fence | ||
+ | |||
+ | |||
+ | Should retract when valve released</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Y212 Hi low pressure</translate> | ||
+ | |Step_Content=<translate>assistance required from colleague | ||
+ | |||
+ | |||
+ | Fire and hold Y80 output , infeed top clamp should move down. Keep Y80 held down | ||
+ | |||
+ | |||
+ | Top clamp block pressure should be weak enough to override by hand and move clamp back towards cylinder | ||
+ | |||
+ | |||
+ | Additionally fire Y212, this should switch clamp to high pressure and stop clamp being able to be over ridden by hand</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_143932.png | ||
+ | |Step_Picture_01=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Y213 Saw blowers</translate> | ||
+ | |Step_Content=<translate>Fire and hold valve | ||
+ | |||
+ | |||
+ | Blowers should switch on | ||
+ | |||
+ | |||
+ | Check operation of inline flow controllers . | ||
+ | |||
+ | |||
+ | When fully closed air flow should stop completely. If air flow can not be completely stopped by flow controller, it is fitted the wrong way around. Change and recheck if this occurs</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Y214 Z turret infeed</translate> | ||
+ | |Step_Content=<translate>Fire and hold valve | ||
+ | |||
+ | |||
+ | Infeed turret should rotate once | ||
+ | |||
+ | |||
+ | Release and fire valve again and turret should again rotate one position</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Y215 Z turret outfeed</translate> | ||
+ | |Step_Content=<translate>Fire and hold valve | ||
+ | |||
+ | Outfeed turret should rotate once | ||
+ | |||
+ | Release and fire valve again and turret should again rotate one position</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Y224 Z support outfeed</translate> | ||
+ | |Step_Content=<translate>Fire and hold valve | ||
+ | |||
+ | Outfeed side z block should fire towards back fence | ||
+ | |||
+ | Should retract when valve released</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_140649.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>output testing complete</translate> | ||
+ | |Step_Content=<translate>Disconnect pcl air supply | ||
+ | |||
+ | |||
+ | Remove temporary blanks fitted</translate> | ||
+ | |Step_Picture_00=R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_135953.png | ||
}} | }} | ||
{{Notes}} | {{Notes}} | ||
{{PageLang | {{PageLang | ||
+ | |Language=en | ||
|SourceLanguage=none | |SourceLanguage=none | ||
|IsTranslation=0 | |IsTranslation=0 | ||
− | |||
}} | }} | ||
{{Tuto Status | {{Tuto Status | ||
|Complete=Draft | |Complete=Draft | ||
}} | }} |
Details for manual pneumatic output testing on module
Auteur Gareth Green | Dernière modification 2/04/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Details for manual pneumatic output testing on module
R0015336_Pneumatic_Output_Testing_Screenshot_2023-10-23_135339.png
Tools Required
PCL airline connection
12mm blanking ports
Valve Manual over ride tool
Standard screwdriver set
Additional colleague when setting regulator pressures for outputs
Parts required
Output testing will require valve operation with no e/s circuit
Ensure the following
Work area is clear from all components not required for testing
All colleagues are aware of the procedure being undertaken
No additional colleagues are working on the module
PCL coupling is accessible to release pressure in case of emergency
Testing procedure is fully adhered to
Wind fully out soft start screw situated on top on main air service unit
Connect main pcl air feed to air service unit
Increase Air service unit pressure to 6.0bar /6mpa
Check for audible leaks on the red pipe lines installed and correct if found
Check air gun regulator functions properly . Fully open the regulator (2 bar limited ) and test air gun assembly
Enable the manual over ride on the main air service unit
This will purge the system with air.
Check for audible leaks on blue Pipe line, and active control pipes to cylinders and regulators
With the system in the natural state when over ridden, the following cylinder positions should be confirmed
Y80 Infeed Top clamp contracted
Y82 Outfeed top clamp contracted
Y91 eject cylinder contracted
Y202 clamp infeed side extended
Y204 Clamp pos contracted
Y206 Centralise contracted
Y207 Saw cut contracted
Y210 Z support infeed contracted
Y213 Saw blowers switched off
Y214 Z turret infeed Not moving
Y215 Z turret outfeed . Not moving
Y224 Z support outfeed contracted
If any deviation from the above check pipe connections to incorrect output
Each valve can be manually fired from the over ride button. Pressing this will activate the valve and fire the cylinder /output
when a valve is over ridden, ensure attention is paid to any new air leaks that could become present in the active line when fired
Fire and hold valve
Adjust regulator to 2 M.P.A
Cylinder should extend
Should retract when valve released
Fire and hold valve
Cylinder should extend
Should retract when valve released
Fire and hold valve
Eject table should move away from saw head
Should retract when valve released
Fire and hold valve
Set regulator to 2 M.P.A
Side clamp should move towards backfence rollers
Should retract when valve released
Fire and hold valve
Clamps should move towards from of machine.
If movement is slow/not present check flow restrictors on back of electrical cabinet identified as 2049
Should retract when valve released
Fire and hold valve
Set regulator to 2 M.P.A
Saw head should move towards rear of machine
Should retract when valve released
Fire and hold valve
Saw head should raise up
Should retract when valve released
Fire and hold valve
Infeed side z block should fire towards back fence
Should retract when valve released
assistance required from colleague
Fire and hold Y80 output , infeed top clamp should move down. Keep Y80 held down
Top clamp block pressure should be weak enough to override by hand and move clamp back towards cylinder
Additionally fire Y212, this should switch clamp to high pressure and stop clamp being able to be over ridden by hand
Fire and hold valve
Blowers should switch on
Check operation of inline flow controllers .
When fully closed air flow should stop completely. If air flow can not be completely stopped by flow controller, it is fitted the wrong way around. Change and recheck if this occurs
Fire and hold valve
Infeed turret should rotate once
Release and fire valve again and turret should again rotate one position
Fire and hold valve
Outfeed turret should rotate once
Release and fire valve again and turret should again rotate one position
Fire and hold valve
Outfeed side z block should fire towards back fence
Should retract when valve released