[version en cours de rédaction] | [version en cours de rédaction] |
Ligne 53 : | Ligne 53 : | ||
}} | }} | ||
{{Tuto Step | {{Tuto Step | ||
− | |Step_Title=<translate> | + | |Step_Title=<translate>Create the clone to pull the latest tc3Multi and PLC_Reset</translate> |
− | |Step_Content=<translate> | + | |Step_Content=<translate>* Create the clone in c:\TwinCAT\[BuildNo]\Source |
+ | * If an error is produced after cloning, just use the "Add" function to add the clone | ||
+ | |||
+ | <br /></translate> | ||
}} | }} | ||
{{Tuto Step | {{Tuto Step | ||
|Step_Title=<translate>Replace the old PLC code with the version control latest</translate> | |Step_Title=<translate>Replace the old PLC code with the version control latest</translate> | ||
|Step_Content=<translate>#Delete the old PLC projects | |Step_Content=<translate>#Delete the old PLC projects | ||
− | #using Add existing item, add the tc3Multi then PLC_Reset projects from c:\TwinCAT\ | + | #using Add existing item, add the tc3Multi then PLC_Reset projects from c:\TwinCAT\[BuildNo]\Source. |
#Ensure Use Original project Location is selected | #Ensure Use Original project Location is selected | ||
#Build the solution to create the instances ready for linking | #Build the solution to create the instances ready for linking | ||
#Ensure the Port numbers are correct (851=tc3Multi, 852=PLC_Project)</translate> | #Ensure the Port numbers are correct (851=tc3Multi, 852=PLC_Project)</translate> | ||
− | |||
− | |||
}} | }} | ||
{{Tuto Step | {{Tuto Step |
How to convert a TwinCAT2 project on an older Autoflow to TwinCAT3. This needs to be done when updating to Windows 10
Auteur Gareth Green | Dernière modification 20/02/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
How to convert a TwinCAT2 project on an older Autoflow to TwinCAT3. This needs to be done when updating to Windows 10
TC2, TC3, TwinCAT Upgrade Convert_Autoflow_TC2_Project_to_TC3_TC3.jpg
You will need to get a backup of the TC2 project from this machine, and use it to set up all the correct IO links in the TC3 project
Add a new route
Navigate to the Adaptor settings and search for the correct one on the new Beckhoff PC
Using System Manager on the Camera PC, create new copies of all the links on all devices from the System Manager to the new project.
The PLC links will be missing - reinstate them as per System Manager on old Camera PC
If The 'Link to PLC' field is not viewable on Twincat 2 project use the below guide for the correct links required:
When converting for a ZX4 machine, the V and W axis links will need to be changed
V = arrAxis[11]
W = arrAxis[12]
In params.saw, the following parameters must be updated
controllerType=5
amsnetId= [AmsNetId of the new Beckhoff PC]
twinCAT Address=[AmsNetId of the new Beckhoff PC]
AllWasteAtStart=1
useSawForYNotch=1
Update
en none 0 Draft