Instructions to fit ancillaries such as wire basket
Auteur Gareth Green | Dernière modification 9/10/2023 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Instructions to fit ancillaries such as wire basket
R0015075b_Fit_Frame_ancillaries_Screenshot_28.png
Tools Required
Standard hex key set
125mm cutting disc /grinder
Standard spanner set
Standard hss drills
Standard tap set
Engineers level
Tape measure
Parts Required
A0001060 x 6
A0001065 x 2
A0001061 x 6
D0015611 x 2
D0015070B x 2Use loctite 243 on all fasteners
Use Loctite 572 on all threaded pneumatic connections
Pen mark all bolts to show finalised
Fit 6 off basket support bracket to pre drilled holes at indicated points .
Secure using M8 x 20 socket caps and Large M8 washers
1 Lay 1 full length of A0001065 wire basket between these points
2 Position end to be mid bracket
3 Allow overhang this end
1 Measure and cut a piece of wire A0001065 wire basket to bridge between indicated points.
2 Measure and cut section of A0001065 to bridge between point 2 indicated
Fix wire baskets to support brackets using 6 off A0001061
Use M6 x 20 button sockets, M6 penny washers and m6 nyloc nuts
Position pad as shown and drill 1 off M6 tapped hole and secure with M6 x 20 socket cap and heavy washer. Use engineers level to level bracket, then mark and drill second M6 tapped hole.
Finalise fasteners, whilst using level to ensure bracket remains level on the indicated plain.
Repeat for 2nd pad position
Mount 2 off D0015070B cabinet braces to indicated point on main frame