[version en cours de rédaction] | [version en cours de rédaction] |
Ligne 200 : | Ligne 200 : | ||
{{Tuto Step | {{Tuto Step | ||
|Step_Title=<translate>Adjust position 4 and 7</translate> | |Step_Title=<translate>Adjust position 4 and 7</translate> | ||
− | |Step_Content=<translate>* Move to position 4 and adjust journal to read 0.00mm on D.T.I | + | |Step_Content=<translate>*Move to position 4 and adjust journal to read 0.00mm on D.T.I |
− | * Move to position 7 and repeat | + | *Move to position 7 and repeat |
Ligne 228 : | Ligne 228 : | ||
|Step_Picture_00=R0000711_Rotary_Base_Assembly_Screenshot_2023-05-30_133058.png | |Step_Picture_00=R0000711_Rotary_Base_Assembly_Screenshot_2023-05-30_133058.png | ||
|Step_Picture_00_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":0,"top":0,"width":595,"height":598,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1.01,"scaleY":1.01,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/d/d9/R0000711_Rotary_Base_Assembly_Screenshot_2023-05-30_133058.png","filters":[]}],"height":603,"width":600} | |Step_Picture_00_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":0,"top":0,"width":595,"height":598,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1.01,"scaleY":1.01,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/d/d9/R0000711_Rotary_Base_Assembly_Screenshot_2023-05-30_133058.png","filters":[]}],"height":603,"width":600} | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Finalise Journal tension</translate> | ||
+ | |Step_Content=<translate>Now the rotary ring is mounted and concentric , journal nuts need to be torqued to the correct tension . | ||
+ | |||
+ | |||
+ | It is vital that the D.T.I is used to gauge if a journal moves when the nut is torqued to the correct setting . | ||
+ | |||
+ | |||
+ | Use the following sequence to set correctly | ||
+ | |||
+ | <br /> | ||
+ | |||
+ | * Use flat hepco spanner to help stop rotation of journal when tightening | ||
+ | * Ensure D.T.I is in front of journal being tightened to indicate if movement occurs | ||
+ | * Use Torque wrench set to 33nm and tension journal nut. | ||
+ | * If the D.T.I indicates movement, it is vital the movement is corrected as this will affect journal contact and concentricity . | ||
+ | * Only move to the next journal when the worked on journal is 100% set and tight | ||
+ | * Mark each journal as tensioned when complete</translate> | ||
+ | |Step_Picture_00=R0000711_Rotary_Base_Assembly_Screenshot_2023-05-30_150028.png | ||
+ | |Step_Picture_01=R0000711_Rotary_Base_Assembly_Screenshot_2023-05-30_150059.png | ||
+ | |Step_Picture_02=R0000711_Rotary_Base_Assembly_Screenshot_2023-05-30_150122.png | ||
+ | |Step_Picture_03=R0000711_Rotary_Base_Assembly_Screenshot_2023-05-30_150939.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Quality Check</translate> | ||
+ | |Step_Content=<translate>After tensioning is complete, recheck concentricity with D.T.I and also check journal tension. | ||
+ | |||
+ | Ring rotation should be smooth but with resistance | ||
+ | |||
+ | No high spots on rotation should be present. | ||
+ | |||
+ | Rotation should be quiet and even sounding | ||
+ | |||
+ | |||
+ | Supervisor check required at this point | ||
+ | |||
+ | |||
+ | |||
+ | <br /></translate> | ||
+ | |Step_Picture_00=R0000711_Rotary_Base_Assembly_quality-assurance-testing.png | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Fit lubricators</translate> | ||
+ | |Step_Content=<translate></translate> | ||
}} | }} | ||
{{Notes}} | {{Notes}} |
Assembly instructions for installation of main rotary drive ring
Auteur Gareth Green | Dernière modification 11/09/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Assembly instructions for installation of main rotary drive ring
R0000711_Rotary_Base_Assembly_Screenshot_2023-05-26_095708.png
Detailed steps to correctly install rotary gear and journals
Checks for correct installation of oil feed system
Tolerance limits and requirements
Tools Required
Standard hex key set
0-25mm micrometer
Ring support blocks for assembly
Work Table
Mag Base and D.T.I
Hepco flat spanner
17mm socket
Torque Wrench
Parts required
D0006423-2mod Drive ring x 1
Rotary drive ring needs checking before fitment.
Check that D0007651faceplate holes indicated (1) are countersunk the same as holes indicated (2 ). If not , countersink to correct
3. Clean all holes with compressed air
Thoroughly clean faceplate with solvent
Journal washers should be inspected to ensure all washers supplied are within tolerance .
Thickness of washer should not exceed 0.05mm difference between all washers supplied. Report any that are incorrect via NCR system
B0000185 and B0000186 journals should be cleaned with compressed air and checked for quality. Visually inspect v grooves of journals for and damage or irregularities
D0007692 should be checked for correct machining. Holes indicated are vital to allow oil flow to ring system once assembled.
Face plate should be positioned ready for assembly
1 Support blocks should be placed either end of faceplate
2 Ensure cut out is orientated correctly as per picture. This is the lifting access point.
3 Ensure correct end of faceplate is located at edge of workstation (end with 6 off M8 tapped holes on indicated face)
Mount journals as shown
Eccentric B0000185 journal 6 off
Concentric B0000186 journal 2 off
Space each journal with D0006503 journal washer
Fit Journal washer and nut to opposite side of mounted journal .
Add light tension to nut, as adjustment will be required
Adjust eccentric journals to their widest point to allow ring gear to be fitted . See point 1 and 2 , these two points need to be as far apart as possible by rotating the eccentric journal with the flat hepco adjustment spanner .
Place hepco drive gear as shown inside journals
The set the initial position of the drive ring the following steps are required
- Journal will rotate when ring in rotated . - Journal can be skidded on ring when held by hand and ring is rotated
- no Rattle is present from movement of ring in a sideways direction
D.T.I and mag base and stand should be mounted to rotary ring as shown
Now it is vital to check the following .
Rotate ring and check all journals can be skidded when held by hand
If yes, Set position 3 and 8 by adjusting journal to read 0.00mm on D.T.I
If no, release pressure on journals 4,5,6 and 7 using D.T.I to gauge movement and reduce 0.00mm reading by 0.01mm
Repeat rotation and skid test, if journals now skid, adjust journals 3 and 8 to new D.T.I setting (-0.01mm)
If no, repeat and reduce pressure by an additional 0.01mm
Repeat these steps until all journals are adjusted to main rotary ring and all can be skidded when held tight on ring rotation.
Maximum tolerance for eccentricity is 0.05mm , so if journals have to be adjusted out of this tolerance, contact supervisor
Now the rotary ring is mounted and concentric , journal nuts need to be torqued to the correct tension .
It is vital that the D.T.I is used to gauge if a journal moves when the nut is torqued to the correct setting .
Use the following sequence to set correctly
After tensioning is complete, recheck concentricity with D.T.I and also check journal tension.
Ring rotation should be smooth but with resistance
No high spots on rotation should be present.
Rotation should be quiet and even sounding
Supervisor check required at this point