Stuertz Welder - Setting Barcode Reader : Différence entre versions

[version en cours de rédaction][version en cours de rédaction]
(Page créée avec « {{Tuto Details |Main_Picture=VSM_Welder_After_Welding_Options_VSM-P-hero.jpg |Main_Picture_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","orig... »)
 
 
Ligne 15 : Ligne 15 :
 
{{EPI}}
 
{{EPI}}
 
{{Tuto Step
 
{{Tuto Step
|Step_Title=<translate>Log in HMI as Software</translate>
+
|Step_Title=<translate>Setup the directory for the welder files</translate>
|Step_Content=<translate></translate>
+
|Step_Content=<translate>There is a "Read Data" button on the welding page for loading current batch.
 +
 
 +
This also allows you to change the file path</translate>
 +
|Step_Picture_00=Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_152703.jpg
 +
|Step_Picture_00_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":0,"top":0,"width":2103,"height":1390,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":0.29,"scaleY":0.29,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/5/59/Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_152703.jpg","filters":[]},{"type":"wfrect","version":"2.4.6","originX":"center","originY":"center","left":549.96,"top":388.18,"width":78.72,"height":17.09,"fill":"rgba(255,0,0,0)","stroke":"#FF0000","strokeWidth":2,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1,"scaleY":1,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"rx":0,"ry":0}],"height":397,"width":600}
 +
|Step_Picture_01=Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_152719.jpg
 +
|Step_Picture_01_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":0,"top":0,"width":2566,"height":1477,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":0.23,"scaleY":0.23,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/9/9e/Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_152719.jpg","filters":[]},{"type":"wfrect","version":"2.4.6","originX":"center","originY":"center","left":308.53,"top":69.81,"width":205.6,"height":91.76,"fill":"rgba(255,0,0,0)","stroke":"#FF0000","strokeWidth":2,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1,"scaleY":1,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"rx":0,"ry":0}],"height":345,"width":600}
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Exit the HMI</translate>
 +
|Step_Content=<translate>To go to windows desktop</translate>
 
}}
 
}}
 
{{Tuto Step
 
{{Tuto Step
Ligne 44 : Ligne 54 :
 
or see the barcode at [https://supportcommunity.zebra.com/s/article/Emulating-a-COM-Serial-Port-Over-USB-using-CDC-driver?language=en_US this address]</translate>
 
or see the barcode at [https://supportcommunity.zebra.com/s/article/Emulating-a-COM-Serial-Port-Over-USB-using-CDC-driver?language=en_US this address]</translate>
 
|Step_Picture_00=Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_151142.jpg
 
|Step_Picture_00=Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_151142.jpg
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Log in HMI as Software</translate>
 +
|Step_Content=<translate>Run HMI
 +
 +
The password in in g:\IT Department\Sturtz Machinery Passwords.txt
 +
 +
{{Warning|...This is a high level security password and should not be distributed beyond commissioning engineers}}<br /></translate>
 
}}
 
}}
 
{{Tuto Step
 
{{Tuto Step
 
|Step_Title=<translate>Select COM port on HMI on the Barcode setting page</translate>
 
|Step_Title=<translate>Select COM port on HMI on the Barcode setting page</translate>
|Step_Content=<translate>Here you can also select length of string and test the barcode reader function</translate>
+
|Step_Content=<translate>Barcode settings are on the features bar on the left hand side
 +
 
 +
Here you can also select length of string and test the barcode reader function</translate>
 
|Step_Picture_00=Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_144256.jpg
 
|Step_Picture_00=Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_144256.jpg
 
|Step_Picture_00_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":-355,"top":14,"width":1374,"height":588,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":0.7,"scaleY":0.7,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/b/ba/Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_144256.jpg","filters":[]}],"height":450.1891551071879,"width":600}
 
|Step_Picture_00_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":-355,"top":14,"width":1374,"height":588,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":0.7,"scaleY":0.7,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/b/ba/Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_144256.jpg","filters":[]}],"height":450.1891551071879,"width":600}
}}
 
{{Tuto Step
 
|Step_Title=<translate>Setup the directory for the barcode files</translate>
 
|Step_Content=<translate>There is a "load file" button on the welding page which allows you to change the file path</translate>
 
 
}}
 
}}
 
{{Notes}}
 
{{Notes}}
 
{{PageLang
 
{{PageLang
 +
|Language=en
 
|SourceLanguage=none
 
|SourceLanguage=none
 
|IsTranslation=0
 
|IsTranslation=0
|Language=en
 
 
}}
 
}}
 
{{Tuto Status
 
{{Tuto Status
 
|Complete=Draft
 
|Complete=Draft
 
}}
 
}}

Version actuelle datée du 28 septembre 2022 à 16:05

Auteur avatarGareth Green | Dernière modification 28/09/2022 par Gareth Green en cours de rédaction

Introduction

How to set up a VSM welder and barcode reader

Étape 1 - Setup the directory for the welder files

There is a "Read Data" button on the welding page for loading current batch.

This also allows you to change the file path


Étape 2 - Exit the HMI

To go to windows desktop

Étape 3 - Install Software to emulate COM port

If this is a Zebra scanner, the Zebra CDC scanner program will be installed already.

For other manufacturers, this may need to be downloaded from the internet




Étape 4 - Open the Device Manager to see the COM Ports



Étape 5 - Enable option to emulate COM port

For a Zebra barcode reader -

Use Reader manual to scan the barcode

or scan the barcode opposite

or see the barcode at this address



Étape 6 - Log in HMI as Software

Run HMI

The password in in g:\IT Department\Sturtz Machinery Passwords.txt

...This is a high level security password and should not be distributed beyond commissioning engineers

Étape 7 - Select COM port on HMI on the Barcode setting page

Barcode settings are on the features bar on the left hand side

Here you can also select length of string and test the barcode reader function



Commentaires

Draft