[version en cours de rédaction] | [version en cours de rédaction] |
(Page créée avec « {{Tuto Details |Main_Picture=VSM_Welder_After_Welding_Options_VSM-P-hero.jpg |Main_Picture_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","orig... ») |
|||
Ligne 15 : | Ligne 15 : | ||
{{EPI}} | {{EPI}} | ||
{{Tuto Step | {{Tuto Step | ||
− | |Step_Title=<translate> | + | |Step_Title=<translate>Setup the directory for the welder files</translate> |
− | |Step_Content=<translate></translate> | + | |Step_Content=<translate>There is a "Read Data" button on the welding page for loading current batch. |
+ | |||
+ | This also allows you to change the file path</translate> | ||
+ | |Step_Picture_00=Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_152703.jpg | ||
+ | |Step_Picture_00_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":0,"top":0,"width":2103,"height":1390,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":0.29,"scaleY":0.29,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/5/59/Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_152703.jpg","filters":[]},{"type":"wfrect","version":"2.4.6","originX":"center","originY":"center","left":549.96,"top":388.18,"width":78.72,"height":17.09,"fill":"rgba(255,0,0,0)","stroke":"#FF0000","strokeWidth":2,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1,"scaleY":1,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"rx":0,"ry":0}],"height":397,"width":600} | ||
+ | |Step_Picture_01=Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_152719.jpg | ||
+ | |Step_Picture_01_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":0,"top":0,"width":2566,"height":1477,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":0.23,"scaleY":0.23,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/9/9e/Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_152719.jpg","filters":[]},{"type":"wfrect","version":"2.4.6","originX":"center","originY":"center","left":308.53,"top":69.81,"width":205.6,"height":91.76,"fill":"rgba(255,0,0,0)","stroke":"#FF0000","strokeWidth":2,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1,"scaleY":1,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"rx":0,"ry":0}],"height":345,"width":600} | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Exit the HMI</translate> | ||
+ | |Step_Content=<translate>To go to windows desktop</translate> | ||
}} | }} | ||
{{Tuto Step | {{Tuto Step | ||
Ligne 44 : | Ligne 54 : | ||
or see the barcode at [https://supportcommunity.zebra.com/s/article/Emulating-a-COM-Serial-Port-Over-USB-using-CDC-driver?language=en_US this address]</translate> | or see the barcode at [https://supportcommunity.zebra.com/s/article/Emulating-a-COM-Serial-Port-Over-USB-using-CDC-driver?language=en_US this address]</translate> | ||
|Step_Picture_00=Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_151142.jpg | |Step_Picture_00=Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_151142.jpg | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Log in HMI as Software</translate> | ||
+ | |Step_Content=<translate>Run HMI | ||
+ | |||
+ | The password in in g:\IT Department\Sturtz Machinery Passwords.txt | ||
+ | |||
+ | {{Warning|...This is a high level security password and should not be distributed beyond commissioning engineers}}<br /></translate> | ||
}} | }} | ||
{{Tuto Step | {{Tuto Step | ||
|Step_Title=<translate>Select COM port on HMI on the Barcode setting page</translate> | |Step_Title=<translate>Select COM port on HMI on the Barcode setting page</translate> | ||
− | |Step_Content=<translate>Here you can also select length of string and test the barcode reader function</translate> | + | |Step_Content=<translate>Barcode settings are on the features bar on the left hand side |
+ | |||
+ | Here you can also select length of string and test the barcode reader function</translate> | ||
|Step_Picture_00=Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_144256.jpg | |Step_Picture_00=Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_144256.jpg | ||
|Step_Picture_00_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":-355,"top":14,"width":1374,"height":588,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":0.7,"scaleY":0.7,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/b/ba/Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_144256.jpg","filters":[]}],"height":450.1891551071879,"width":600} | |Step_Picture_00_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":-355,"top":14,"width":1374,"height":588,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":0.7,"scaleY":0.7,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/b/ba/Stuertz_Welder_-_Setting_Barcode_Reader_Screenshot_2022-09-28_144256.jpg","filters":[]}],"height":450.1891551071879,"width":600} | ||
− | |||
− | |||
− | |||
− | |||
}} | }} | ||
{{Notes}} | {{Notes}} | ||
{{PageLang | {{PageLang | ||
+ | |Language=en | ||
|SourceLanguage=none | |SourceLanguage=none | ||
|IsTranslation=0 | |IsTranslation=0 | ||
− | |||
}} | }} | ||
{{Tuto Status | {{Tuto Status | ||
|Complete=Draft | |Complete=Draft | ||
}} | }} |
Setting up a VSM barcode reader
Auteur Gareth Green | Dernière modification 28/09/2022 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Setting up a VSM barcode reader
VSM, Barcode VSM_Welder_After_Welding_Options_VSM-P-hero.jpg
There is a "Read Data" button on the welding page for loading current batch.
This also allows you to change the file path
To go to windows desktop
If this is a Zebra scanner, the Zebra CDC scanner program will be installed already.
For other manufacturers, this may need to be downloaded from the internet
For a Zebra barcode reader -
Use Reader manual to scan the barcode
or scan the barcode opposite
or see the barcode at this address
Run HMI
The password in in g:\IT Department\Sturtz Machinery Passwords.txt
Barcode settings are on the features bar on the left hand side
Here you can also select length of string and test the barcode reader function
en none 0 Draft
Vous avez entré un nom de page invalide, avec un ou plusieurs caractères suivants :
< > @ ~ : * € £ ` + = / \ | [ ] { } ; ? #