Microline withTwinCAT3 Setup Notes : Différence entre versions

[version en cours de rédaction][version en cours de rédaction]
Ligne 21 : Ligne 21 :
 
Disabled alarm for Ipull out - this was a misleading error when it is loading to gripper  
 
Disabled alarm for Ipull out - this was a misleading error when it is loading to gripper  
  
= Tuning X axis drive =
+
=Tuning X axis drive=
 
Following error on X axis stopped the axis on loading
 
Following error on X axis stopped the axis on loading
  
Ligne 44 : Ligne 44 :
  
 
Set at 100%. Seems to easy
 
Set at 100%. Seems to easy
 +
 +
= Spindles =
 +
invert300Hz=1
 +
 +
InverterOkHigh=1
 +
 +
Input In_InvOk mapped to 90 and configured in alarms
 +
 +
ringType=Mk3with DP
 +
 
<br /></translate>
 
<br /></translate>
 
{{PageLang
 
{{PageLang

Version du 24 août 2022 à 11:25

Auteur avatarGareth Green | Dernière modification 21/09/2022 par Gareth Green en cours de rédaction

Pas encore d'image

Notes on issues encountered with Microline transfer to TwinCAT3 setup

In_OCUT1 / LOADD

The infeed 2007 does not have a LOADD sensor.

Confusion over how the code can handle this. It must have worked ok on other infeeds like this (eg Z046).

When investigating in the code, errors found on function blocks fbMotorConvey on inputs to

iArrayError

bNoSensorsCovered

iMeasureErrorMsg

These normally connect to fbArrayMeasure function block, but this does not exist in MHInfeed_2007

Alarms

Disabled alarm for Ipull out - this was a misleading error when it is loading to gripper

Tuning X axis drive

Following error on X axis stopped the axis on loading

When tuning took place, the bar was not clamped

Tried a reversing move with clamps on.

At Speed 10, following error was 0.2

At speed 50, following error was 1

At speed 100, the following error was 2mm

This shows a proportional increse in following error as spee increases


Tried changing drive P-Gain, no effect

Changed 3.02 Kff Gain (feed forward. Was on zero

Following error dropped proportionally to ff gain 0-100%

Set at 100%. Seems to easy

Spindles

invert300Hz=1

InverterOkHigh=1

Input In_InvOk mapped to 90 and configured in alarms

ringType=Mk3with DP


Commentaires

Draft