[version en cours de rédaction] | [version en cours de rédaction] |
(Une révision intermédiaire par le même utilisateur non affichée) | |||
Ligne 2 : | Ligne 2 : | ||
|Description=<translate>How to disable input channels from winMulti</translate> | |Description=<translate>How to disable input channels from winMulti</translate> | ||
|Categories=Software | |Categories=Software | ||
− | |Tags=disable, input, timeout | + | |Tags=disable, input, timeout, ioDisable |
}} | }} | ||
<translate>{{Dont|...This is a feature added in front end software v6.4.51.0 and back end 6.3048 - TwinCAT3 machine only}} | <translate>{{Dont|...This is a feature added in front end software v6.4.51.0 and back end 6.3048 - TwinCAT3 machine only}} | ||
Ligne 35 : | Ligne 35 : | ||
OuF_Saw90,208,2,0,0,False,False,2,1,-,False,0,Y20,False,-1 | OuF_Saw90,208,2,0,0,False,False,2,1,-,False,0,Y20,False,-1 | ||
− | </syntaxhighlight><br /></translate> | + | </syntaxhighlight> |
+ | |||
+ | = Standalone Saw Infeed Table with one Material Load Input = | ||
+ | Older standalone saw infeed tables have only one material load input to serve two switches that are linked in series. Newer tables have two separate inputs. | ||
+ | |||
+ | This feature can be used to disable the MatlLoaded2 sensor if it does not exist | ||
+ | <br />{{#annotatedImageLight:Fichier:WinMulti - Disabling Input Channels MatlLoad2.png|0=800px|hash=9c700e26c1d938179cd9d9a0497b0a74|jsondata={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":0,"top":0,"width":1378,"height":852,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":0.58,"scaleY":0.58,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/b/b5/WinMulti_-_Disabling_Input_Channels_MatlLoad2.png","filters":[]},{"type":"wfrect","version":"2.4.6","originX":"center","originY":"center","left":609.43,"top":174.56,"width":268.83,"height":26.33,"fill":"rgba(255,0,0,0)","stroke":"#FF0000","strokeWidth":2,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1,"scaleY":1,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"rx":0,"ry":0}],"height":495,"width":800}|mediaClass=Image|type=frameless|align=center|src=/images/thumb/b/b5/WinMulti_-_Disabling_Input_Channels_MatlLoad2.png/ia-9c700e26c1d938179cd9d9a0497b0a74-px-WinMulti_-_Disabling_Input_Channels_MatlLoad2.png.png|href=./Fichier:WinMulti - Disabling Input Channels MatlLoad2.png|resource=./Fichier:WinMulti - Disabling Input Channels MatlLoad2.png|caption=|size=800px}}<br /><syntaxhighlight> | ||
+ | InA_MatlLoaded1,31,1,0,0,False,False,0,2,-,False,0,X31,False,-1 | ||
+ | InA_MatlLoaded2,32,1,0,0,False,False,0,3,-,False,0,X32,True,-1 | ||
+ | InA_AirOk,43,1,0,0,False,False,0,1,-,False,0,X43,False,-1 | ||
+ | InA_EStop,45,1,0,0,False,False,0,4,-,False,0,X45,False,-1 | ||
+ | InA_ButReset,48,0,0,0,False,False,1,1,-,False,0,X48,False,-1 | ||
+ | |||
+ | </syntaxhighlight> | ||
+ | |||
+ | |||
+ | |||
+ | <br /></translate> | ||
{{PageLang | {{PageLang | ||
|Language=en | |Language=en |
How to disable input channels from winMulti
Auteur Gareth Green | Dernière modification 30/03/2021 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Pas encore d'image
How to disable input channels from winMulti
disable, input, timeout, ioDisable
This feature allows the engineer to disable inputs through the front end. This has the uses outlined below
If an eject home or out sensor is faulty, this can stop the machine from functioning. On v5 software, the operator could press escape to keep running. this feature is not available on v6 software. This update allows one or both of these sensors to be disabled and replaced with a timeout.
This is done through the IO Map setting screen:
The above screenshot shows the Eject push home input disabled and a timeout of 5000ms (5 seconds) used in place
On original saws before S092, the saw position at 135 and 45 degrees was fed via one input - Saw45. This meant that the saw135 input had to be physically wired into a different IO channel. the update allows this input to be disabled
This is done through the IO Map setting screen - tick the disable box for the Saw135 input:
If the input is not there, it need to be added in the ioDef file:
InF_Saw45,191,1,0,0,False,False,3,7,-,False,0,X14,False,-1
InF_Saw90,192,1,0,0,False,False,3,8,-,False,0,X24,False,-1
InF_Saw135,197,1,0,0,False,False,3,9,-,False,0,X197,False,-1
InF_Guard,196,1,0,0,False,False,0,3,-,False,0,X16,False,-1
OuF_Saw90,208,2,0,0,False,False,2,1,-,False,0,Y20,False,-1
Older standalone saw infeed tables have only one material load input to serve two switches that are linked in series. Newer tables have two separate inputs.
This feature can be used to disable the MatlLoaded2 sensor if it does not exist
InA_MatlLoaded1,31,1,0,0,False,False,0,2,-,False,0,X31,False,-1
InA_MatlLoaded2,32,1,0,0,False,False,0,3,-,False,0,X32,True,-1
InA_AirOk,43,1,0,0,False,False,0,1,-,False,0,X43,False,-1
InA_EStop,45,1,0,0,False,False,0,4,-,False,0,X45,False,-1
InA_ButReset,48,0,0,0,False,False,1,1,-,False,0,X48,False,-1
en
none
0
Draft
Vous avez entré un nom de page invalide, avec un ou plusieurs caractères suivants :
< > @ ~ : * € £ ` + = / \ | [ ] { } ; ? #